| /* SPDX-License-Identifier: LGPL-2.1-or-later */ |
| |
| #include "bus-error.h" |
| #include "bus-locator.h" |
| #include "bus-wait-for-units.h" |
| #include "systemctl-clean-or-freeze.h" |
| #include "systemctl-util.h" |
| #include "systemctl.h" |
| |
| int clean_or_freeze_unit(int argc, char *argv[], void *userdata) { |
| _cleanup_(bus_wait_for_units_freep) BusWaitForUnits *w = NULL; |
| _cleanup_strv_free_ char **names = NULL; |
| int r, ret = EXIT_SUCCESS; |
| char **name; |
| const char *method; |
| sd_bus *bus; |
| |
| r = acquire_bus(BUS_FULL, &bus); |
| if (r < 0) |
| return r; |
| |
| polkit_agent_open_maybe(); |
| |
| if (!arg_clean_what) { |
| arg_clean_what = strv_new("cache", "runtime"); |
| if (!arg_clean_what) |
| return log_oom(); |
| } |
| |
| r = expand_unit_names(bus, strv_skip(argv, 1), NULL, &names, NULL); |
| if (r < 0) |
| return log_error_errno(r, "Failed to expand names: %m"); |
| |
| if (!arg_no_block) { |
| r = bus_wait_for_units_new(bus, &w); |
| if (r < 0) |
| return log_error_errno(r, "Failed to allocate unit waiter: %m"); |
| } |
| |
| if (streq(argv[0], "clean")) |
| method = "CleanUnit"; |
| else if (streq(argv[0], "freeze")) |
| method = "FreezeUnit"; |
| else if (streq(argv[0], "thaw")) |
| method = "ThawUnit"; |
| else |
| assert_not_reached("Unhandled method"); |
| |
| STRV_FOREACH(name, names) { |
| _cleanup_(sd_bus_error_free) sd_bus_error error = SD_BUS_ERROR_NULL; |
| _cleanup_(sd_bus_message_unrefp) sd_bus_message *m = NULL; |
| |
| if (w) { |
| /* If we shall wait for the cleaning to complete, let's add a ref on the unit first */ |
| r = bus_call_method(bus, bus_systemd_mgr, "RefUnit", &error, NULL, "s", *name); |
| if (r < 0) { |
| log_error_errno(r, "Failed to add reference to unit %s: %s", *name, bus_error_message(&error, r)); |
| if (ret == EXIT_SUCCESS) |
| ret = r; |
| continue; |
| } |
| } |
| |
| r = bus_message_new_method_call(bus, &m, bus_systemd_mgr, method); |
| if (r < 0) |
| return bus_log_create_error(r); |
| |
| r = sd_bus_message_append(m, "s", *name); |
| if (r < 0) |
| return bus_log_create_error(r); |
| |
| if (streq(method, "CleanUnit")) { |
| r = sd_bus_message_append_strv(m, arg_clean_what); |
| if (r < 0) |
| return bus_log_create_error(r); |
| } |
| |
| r = sd_bus_call(bus, m, 0, &error, NULL); |
| if (r < 0) { |
| log_error_errno(r, "Failed to %s unit %s: %s", argv[0], *name, bus_error_message(&error, r)); |
| if (ret == EXIT_SUCCESS) { |
| ret = r; |
| continue; |
| } |
| } |
| |
| if (w) { |
| r = bus_wait_for_units_add_unit(w, *name, BUS_WAIT_REFFED|BUS_WAIT_FOR_MAINTENANCE_END, NULL, NULL); |
| if (r < 0) |
| return log_error_errno(r, "Failed to watch unit %s: %m", *name); |
| } |
| } |
| |
| r = bus_wait_for_units_run(w); |
| if (r < 0) |
| return log_error_errno(r, "Failed to wait for units: %m"); |
| if (r == BUS_WAIT_FAILURE) |
| ret = EXIT_FAILURE; |
| |
| return ret; |
| } |