| <?xml version='1.0'?> |
| <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN" |
| "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd"> |
| |
| <!-- |
| SPDX-License-Identifier: LGPL-2.1+ |
| |
| Copyright © 2016 Julian Orth |
| --> |
| |
| <refentry id="sd_bus_get_fd" xmlns:xi="http://www.w3.org/2001/XInclude"> |
| |
| <refentryinfo> |
| <title>sd_bus_get_fd</title> |
| <productname>systemd</productname> |
| </refentryinfo> |
| |
| <refmeta> |
| <refentrytitle>sd_bus_get_fd</refentrytitle> |
| <manvolnum>3</manvolnum> |
| </refmeta> |
| |
| <refnamediv> |
| <refname>sd_bus_get_fd</refname> |
| <refname>sd_bus_get_events</refname> |
| <refname>sd_bus_get_timeout</refname> |
| |
| <refpurpose>Get the file descriptor, I/O events and time-out to wait for from a message bus object</refpurpose> |
| </refnamediv> |
| |
| <refsynopsisdiv> |
| <funcsynopsis> |
| <funcsynopsisinfo>#include <systemd/sd-bus.h></funcsynopsisinfo> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_get_fd</function></funcdef> |
| <paramdef>sd_bus *<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_get_events</function></funcdef> |
| <paramdef>sd_bus *<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_get_timeout</function></funcdef> |
| <paramdef>sd_bus *<parameter>bus</parameter></paramdef> |
| <paramdef>uint64_t *<parameter>timeout_usec</parameter></paramdef> |
| </funcprototype> |
| </funcsynopsis> |
| </refsynopsisdiv> |
| |
| <refsect1> |
| <title>Description</title> |
| |
| <para><function>sd_bus_get_fd()</function> returns the file descriptor used to communicate from a message bus |
| object. This descriptor can be used with <citerefentry |
| project='man-pages'><refentrytitle>poll</refentrytitle><manvolnum>3</manvolnum></citerefentry> or a similar |
| function to wait for I/O events on the specified bus connection object. If the bus object was configured with the |
| <citerefentry><refentrytitle>sd_bus_set_fd</refentrytitle><manvolnum>3</manvolnum></citerefentry> function, then |
| the <parameter>input_fd</parameter> file descriptor used in that call is returned.</para> |
| |
| <para><function>sd_bus_get_events()</function> returns the I/O events to wait for, suitable for passing to |
| <function>poll()</function> or a similar call. Returns a combination of <constant>POLLIN</constant>, |
| <constant>POLLOUT</constant>, … events, or negative on error.</para> |
| |
| <para><function>sd_bus_get_timeout()</function> returns the time-out in µs to pass to to |
| <function>poll()</function> or a similar call when waiting for events on the specified bus connection. The returned |
| time-out may be zero, in which case a subsequent I/O polling call should be invoked in non-blocking mode. The |
| returned timeout may be <constant>UINT64_MAX</constant> in which case the I/O polling call may block indefinitely, |
| without any applied time-out. Note that the returned time-out should be considered only a maximum sleeping time. It |
| is permissible (and even expected) that shorter time-outs are used by the calling program, in case other event |
| sources are polled in the same event loop. Note that the returned time-value is relative and specified in |
| microseconds. When converting this value in order to pass it as third argument to <function>poll()</function> |
| (which expects milliseconds), care should be taken to use a division that rounds up to ensure the I/O polling |
| operation doesn't sleep for shorter than necessary, which might result in unintended busy looping (alternatively, |
| use <citerefentry project='man-pages'><refentrytitle>ppoll</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| instead of plain <function>poll()</function>, which understands time-outs with nano-second granularity).</para> |
| |
| <para>These three functions are useful to hook up a bus connection object with an external or manual event loop |
| involving <function>poll()</function> or a similar I/O polling call. Before each invocation of the I/O polling |
| call, all three functions should be invoked: the file descriptor returned by <function>sd_bus_get_fd()</function> |
| should be polled for the events indicated by <function>sd_bus_get_events()</function>, and the I/O call should |
| block for that up to the time-out returned by <function>sd_bus_get_timeout()</function>. After each I/O polling |
| call the bus connection needs to process incoming or outgoing data, by invoking |
| <citerefentry><refentrytitle>sd_bus_process</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para> |
| |
| <para>Note that these function are only one of three supported ways to implement I/O event handling for bus |
| connections. Alternatively use |
| <citerefentry><refentrytitle>sd_bus_attach_event</refentrytitle><manvolnum>3</manvolnum></citerefentry> to attach a |
| bus connection to an <citerefentry><refentrytitle>sd-event</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| event loop. Or use <citerefentry><refentrytitle>sd_bus_wait</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| as a simple synchronous, blocking I/O waiting call.</para> |
| </refsect1> |
| |
| <refsect1> |
| <title>Return Value</title> |
| |
| <para><function>sd_bus_get_fd()</function> returns the file descriptor used for communication, or a negative |
| <varname>errno</varname>-style error code on error.</para> |
| |
| <para><function>sd_bus_get_events()</function> returns the I/O event mask to use for I/O event watching, or a |
| negative <varname>errno</varname>-style error code on error.</para> |
| |
| <para><function>sd_bus_get_timeout()</function> returns zero or positive on success, or a negative |
| <varname>errno</varname>-style error code on error.</para> |
| </refsect1> |
| |
| <refsect1> |
| <title>Errors</title> |
| |
| <para>Returned errors may indicate the following problems:</para> |
| |
| <variablelist> |
| <varlistentry> |
| <term><constant>-EINVAL</constant></term> |
| |
| <listitem><para>An invalid bus object was passed.</para></listitem> |
| </varlistentry> |
| |
| <varlistentry> |
| <term><constant>-ECHILD</constant></term> |
| |
| <listitem><para>The bus connection was allocated in a parent process and is being reused in a child process |
| after <function>fork()</function>.</para></listitem> |
| </varlistentry> |
| |
| <varlistentry> |
| <term><constant>-ENOTCONN</constant></term> |
| |
| <listitem><para>The bus connection has been terminated.</para></listitem> |
| </varlistentry> |
| |
| <varlistentry> |
| <term><constant>-EPERM</constant></term> |
| |
| <listitem><para>Two distinct file descriptors were passed for input and output using |
| <function>sd_bus_set_fd()</function>, which <function>sd_bus_get_fd()</function> cannot |
| return.</para></listitem> |
| </varlistentry> |
| </variablelist> |
| </refsect1> |
| |
| <xi:include href="libsystemd-pkgconfig.xml" /> |
| |
| <refsect1> |
| <title>See Also</title> |
| |
| <para> |
| <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_set_fd</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_process</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_attach_event</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_wait</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry project='man-pages'><refentrytitle>poll</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| </para> |
| </refsect1> |
| |
| </refentry> |