| <?xml version='1.0'?> <!--*- Mode: nxml; nxml-child-indent: 2; indent-tabs-mode: nil -*--> |
| <!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.2//EN" |
| "http://www.oasis-open.org/docbook/xml/4.2/docbookx.dtd"> |
| |
| <!-- |
| SPDX-License-Identifier: LGPL-2.1+ |
| |
| This file is part of systemd. |
| |
| Copyright 2014 Zbigniew Jędrzejewski-Szmek |
| |
| systemd is free software; you can redistribute it and/or modify it |
| under the terms of the GNU Lesser General Public License as published by |
| the Free Software Foundation; either version 2.1 of the License, or |
| (at your option) any later version. |
| |
| systemd is distributed in the hope that it will be useful, but |
| WITHOUT ANY WARRANTY; without even the implied warranty of |
| MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU |
| Lesser General Public License for more details. |
| |
| You should have received a copy of the GNU Lesser General Public License |
| along with systemd; If not, see <http://www.gnu.org/licenses/>. |
| --> |
| |
| <refentry id="sd_bus_default"> |
| |
| <refentryinfo> |
| <title>sd_bus_default</title> |
| <productname>systemd</productname> |
| |
| <authorgroup> |
| <author> |
| <contrib>A monkey with a typewriter</contrib> |
| <firstname>Zbigniew</firstname> |
| <surname>Jędrzejewski-Szmek</surname> |
| <email>zbyszek@in.waw.pl</email> |
| </author> |
| </authorgroup> |
| </refentryinfo> |
| |
| <refmeta> |
| <refentrytitle>sd_bus_default</refentrytitle> |
| <manvolnum>3</manvolnum> |
| </refmeta> |
| |
| <refnamediv> |
| <refname>sd_bus_default</refname> |
| <refname>sd_bus_default_user</refname> |
| <refname>sd_bus_default_system</refname> |
| |
| <refname>sd_bus_open</refname> |
| <refname>sd_bus_open_user</refname> |
| <refname>sd_bus_open_system</refname> |
| <refname>sd_bus_open_system_remote</refname> |
| <refname>sd_bus_open_system_machine</refname> |
| |
| <refpurpose>Acquire a connection to a system or user bus</refpurpose> |
| </refnamediv> |
| |
| <refsynopsisdiv> |
| <funcsynopsis> |
| <funcsynopsisinfo>#include <systemd/sd-bus.h></funcsynopsisinfo> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_default</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_default_user</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_default_system</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_open</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_open_user</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_open_system</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_open_system_remote</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| <paramdef>const char *<parameter>host</parameter></paramdef> |
| </funcprototype> |
| |
| <funcprototype> |
| <funcdef>int <function>sd_bus_open_system_machine</function></funcdef> |
| <paramdef>sd_bus **<parameter>bus</parameter></paramdef> |
| <paramdef>const char *<parameter>machine</parameter></paramdef> |
| </funcprototype> |
| |
| </funcsynopsis> |
| </refsynopsisdiv> |
| |
| <refsect1> |
| <title>Description</title> |
| |
| <para><function>sd_bus_default()</function> acquires a bus |
| connection object to the user bus when invoked in user context, or |
| to the system bus otherwise. The connection object is associated |
| with the calling thread. Each time the function is invoked from |
| the same thread, the same object is returned, but its reference |
| count is increased by one, as long as at least one reference is |
| kept. When the last reference to the connection is dropped (using |
| the |
| <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| call), the connection is terminated. Note that the connection is |
| not automatically terminated when the associated thread ends. It |
| is important to drop the last reference to the bus connection |
| explicitly before the thread ends, as otherwise, the connection will |
| leak. Also, queued but unread or unwritten messages keep the |
| bus referenced, see below.</para> |
| |
| <para><function>sd_bus_default_user()</function> returns a user |
| bus connection object associated with the calling thread. |
| <function>sd_bus_default_system()</function> is similar, but |
| connects to the system bus. Note that |
| <function>sd_bus_default()</function> is identical to these two |
| calls, depending on the execution context.</para> |
| |
| <para><function>sd_bus_open()</function> creates a new, |
| independent bus connection to the user bus when invoked in user |
| context, or the system bus |
| otherwise. <function>sd_bus_open_user()</function> is similar, but |
| connects only to the user bus. |
| <function>sd_bus_open_system()</function> does the same, but |
| connects to the system bus. In contrast to |
| <function>sd_bus_default()</function>, |
| <function>sd_bus_default_user()</function>, and |
| <function>sd_bus_default_system()</function>, these calls return |
| new, independent connection objects that are not associated with |
| the invoking thread and are not shared between multiple |
| invocations. It is recommended to share connections per thread to |
| efficiently make use the available resources. Thus, it is |
| recommended to use <function>sd_bus_default()</function>, |
| <function>sd_bus_default_user()</function> and |
| <function>sd_bus_default_system()</function> to connect to the |
| user or system buses.</para> |
| |
| <para>If the <varname>$DBUS_SESSION_BUS_ADDRESS</varname> environment |
| variable is set |
| (cf. <citerefentry project='man-pages'><refentrytitle>environ</refentrytitle><manvolnum>7</manvolnum></citerefentry>), |
| it will be used as the address of the user bus. This variable can |
| contain multiple addresses separated by <literal>;</literal>. If |
| this variable is not set, a suitable default for the default user |
| D-Bus instance will be used.</para> |
| |
| <para>If the <varname>$DBUS_SYSTEM_BUS_ADDRESS</varname> |
| environment variable is set, it will be used as the address of the |
| system bus. This variable uses the same syntax as |
| <varname>$DBUS_SESSION_BUS_ADDRESS</varname>. If this variable is |
| not set, a suitable default for the default system D-Bus instance |
| will be used.</para> |
| |
| <para><function>sd_bus_open_system_remote()</function> connects to the system bus on |
| the specified host using |
| <citerefentry project='die-net'><refentrytitle>ssh</refentrytitle><manvolnum>1</manvolnum></citerefentry>. |
| <parameter>host</parameter> consists of an optional user name followed by the |
| <literal>@</literal> symbol, and the hostname, optionally followed by a |
| <literal>:</literal> and a machine name. If the machine name is given, a connection |
| is created to the system bus in the specified container on the remote machine, and |
| otherwise a connection to the system bus on the specified host is created.</para> |
| |
| <para>Note that entering a container is a privileged operation, and will likely only |
| work for the root user on the remote machine.</para> |
| |
| <para><function>sd_bus_open_system_machine()</function> connects |
| to the system bus in the specified <parameter>machine</parameter>, |
| where <parameter>machine</parameter> is the name of a local |
| container. See |
| <citerefentry><refentrytitle>machinectl</refentrytitle><manvolnum>1</manvolnum></citerefentry> |
| for more information about the "machine" concept. Note that |
| connections into local containers are only available to privileged |
| processes at this time.</para> |
| |
| <para>These calls allocate a bus connection object and initiate |
| the connection to a well-known bus of some form. An alternative to |
| using these high-level calls is to create an unconnected bus |
| object with |
| <citerefentry><refentrytitle>sd_bus_new</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| and to connect it with |
| <citerefentry><refentrytitle>sd_bus_start</refentrytitle><manvolnum>3</manvolnum></citerefentry>. |
| </para> |
| |
| </refsect1> |
| |
| <refsect1> |
| <title>Reference ownership</title> |
| <para>The functions <function>sd_bus_open()</function>, |
| <function>sd_bus_open_user()</function>, |
| <function>sd_bus_open_system()</function>, |
| <function>sd_bus_open_system_remote()</function>, and |
| <function>sd_bus_open_system_machine()</function> return a new |
| connection object and the caller owns the sole reference. When not |
| needed anymore, this reference should be destroyed with |
| <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>. |
| </para> |
| |
| <para>The functions <function>sd_bus_default()</function>, |
| <function>sd_bus_default_user()</function> and |
| <function>sd_bus_default_system()</function> do not necessarily |
| create a new object, but increase the connection reference of an |
| existing connection object by one. Use |
| <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry> |
| to drop the reference.</para> |
| |
| <para>Queued but unwritten/unread messages also keep a reference |
| to their bus connection object. For this reason, even if an |
| application dropped all references to a bus connection, it might |
| not get destroyed right away. Until all incoming queued |
| messages are read, and until all outgoing unwritten messages are |
| written, the bus object will stay |
| alive. <function>sd_bus_flush()</function> may be used to write |
| all outgoing queued messages so they drop their references. To |
| flush the unread incoming messages, use |
| <function>sd_bus_close()</function>, which will also close the bus |
| connection. When using the default bus logic, it is a good idea to |
| first invoke <function>sd_bus_flush()</function> followed by |
| <function>sd_bus_close()</function> when a thread or process |
| terminates, and thus its bus connection object should be |
| freed.</para> |
| |
| <para>The life cycle of the default bus connection should be the |
| responsibility of the code that creates/owns the thread the |
| default bus connection object is associated with. Library code |
| should neither call <function>sd_bus_flush()</function> nor |
| <function>sd_bus_close()</function> on default bus objects unless |
| it does so in its own private, self-allocated thread. Library code |
| should not use the default bus object in other threads unless it |
| is clear that the program using it will life cycle the bus |
| connection object and flush and close it before exiting from the |
| thread. In libraries where it is not clear that the calling |
| program will life cycle the bus connection object, it is hence |
| recommended to use <function>sd_bus_open_system()</function> |
| instead of <function>sd_bus_default_system()</function> and |
| related calls.</para> |
| </refsect1> |
| |
| <refsect1> |
| <title>Return Value</title> |
| |
| <para>On success, these calls return 0 or a positive |
| integer. On failure, these calls return a negative |
| errno-style error code.</para> |
| </refsect1> |
| |
| <refsect1> |
| <title>Errors</title> |
| |
| <para>Returned errors may indicate the following problems:</para> |
| |
| <variablelist> |
| |
| <varlistentry> |
| <term><constant>-EINVAL</constant></term> |
| |
| <listitem><para>The specified parameters are invalid.</para></listitem> |
| </varlistentry> |
| |
| <varlistentry> |
| <term><constant>-ENOMEM</constant></term> |
| |
| <listitem><para>Memory allocation failed.</para></listitem> |
| </varlistentry> |
| |
| <varlistentry> |
| <term><constant>-ESOCKTNOSUPPORT</constant></term> |
| |
| <listitem><para>The protocol version required to connect to the selected bus is not supported.</para></listitem> |
| </varlistentry> |
| </variablelist> |
| |
| <para>In addition, any further connection-related errors may be |
| by returned. See <citerefentry><refentrytitle>sd_bus_send</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para> |
| </refsect1> |
| |
| <refsect1> |
| <title>Notes</title> |
| |
| <para><function>sd_bus_open_user()</function> and the other |
| functions described here are available as a shared library, which |
| can be compiled and linked to with the |
| <constant>libsystemd</constant> <citerefentry |
| project='die-net'><refentrytitle>pkg-config</refentrytitle><manvolnum>1</manvolnum></citerefentry> |
| file.</para> |
| </refsect1> |
| |
| <refsect1> |
| <title>See Also</title> |
| |
| <para> |
| <citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_new</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_ref</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>sd_bus_unref</refentrytitle><manvolnum>3</manvolnum></citerefentry>, |
| <citerefentry project='die-net'><refentrytitle>ssh</refentrytitle><manvolnum>1</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>systemd-machined.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>, |
| <citerefentry><refentrytitle>machinectl</refentrytitle><manvolnum>1</manvolnum></citerefentry> |
| </para> |
| </refsect1> |
| |
| </refentry> |