SIMH/HP 2100 RELEASE NOTES | |
========================== | |
Last update: 2017-09-06 | |
This file documents the release history of the simulator for the Hewlett-Packard | |
2114, 2115, 2116, 2100, 1000-M, 1000-E, and 1000-F machines. | |
The SIMH project does not issue discrete releases. Instead, the current | |
simulator code base is available at: | |
https://github.com/simh/simh | |
...and may be downloaded at any time. A code snapshot is identified by the "git | |
commit ID" that is displayed in the simulator welcome banner. | |
Therefore, HP 2100 releases are simply documentation checkpoints that describe | |
the changes that have occurred since the last checkpoint. Generally, a release | |
is written when one or more major changes have been incorporated. Minor bug | |
fixes will be available immediately from the repository but only noted as part | |
of the next release document. | |
=============================== | |
Reporting Bugs in the Simulator | |
=============================== | |
If you find a bug in the HP 2100 simulator, please report it either to the SIMH | |
issue tracker on github at: | |
https://github.com/simh/simh/issues | |
...or to the SIMH mailing list; see: | |
http://mailman.trailing-edge.com/mailman/listinfo/simh | |
...for subscribing information. In either case, please include a console log | |
that contains a reproducible test case that illustrates the problem. See the | |
"Recording Simulator Activities" section of the "SIMH User's Guide" for details. | |
=================== | |
General Information | |
=================== | |
The simulator passes the HP 24396 offline diagnostic suite with some expected | |
failures due to unimplemented features. For example, the disc diagnostic | |
error-correction logic tests and the tape diagnostic CRCC and LRCC tests fail, | |
as these features are not supported. However, all features that are required | |
for operation of the supported HP operating systems pass their respective | |
diagnostic tests. See the accompanying "hp2100_diag.txt" file for details. | |
The simulator has been tested with the following operating systems: | |
- SIO, BCS, and MTS. | |
- 2000E, 2000F, and 2000/Access Time-Shared BASIC. | |
- DOS, DOS-M, and DOS-III. | |
- RTE, RTE-B, RTE-C, RTE-II, RTE-III, RTE-IV, RTE-IVB, and RTE-6/VM. | |
The user's manual for the simulator is provided in Microsoft Word format in the | |
"doc" subdirectory of the code base snapshot downloaded from the github site. A | |
PDF version of the same manual is available at: | |
http://alum.mit.edu/www/jdbryan/hp2100_doc.pdf | |
------------------ | |
Available Software | |
------------------ | |
A preconfigured RTE-6/VM disc image containing the operating system, the MACRO | |
assembler and Fortran 77 compiler, a selection of tape backup and restore | |
programs (READT/WRITT, READR/SAVER, FC, TF, and FST), an example programs | |
(/KENC/HELLO.FTN), and the Mystery Mansion game (MMM) is available from | |
Bitsavers at: | |
http://www.bitsavers.org/bits/HP/tapes/rte-6vm/rte6200/ | |
The archive contains instructions and simulator command files that allow | |
ready-to-run operation. | |
The Computer History Museum has graciously arranged with HP to offer the HP 1000 | |
Software Collection with a sublicense for non-commercial use by private | |
individuals. The Collection is hosted by Bitsavers at: | |
http://www.bitsavers.org/bits/HP/HP_1000_software_collection/ | |
A preconfigured RTE-IVB disc image containing the operating system, the ASMB | |
assembler and FORTRAN IV compiler, and the READR/SAVER and FC tape backup and | |
restore programs is available from the HP Computer Museum at: | |
http://www.hpmuseum.net/display_item.php?sw=565 | |
The archive contains instructions and a simulator command file. | |
QCTerm, an HP 700 terminal emulator for Microsoft Windows, is available from the | |
HP Computer Museum at: | |
http://www.hpmuseum.net/display_item.php?sw=585 | |
Use of an HP terminal via a serial port or terminal emulator via Telnet enables | |
more advanced screen editing features of the RTE operating systems. | |
Manuals describing the operation of HP software are available from Bitsavers at: | |
http://www.bitsavers.org/pdf/hp/1000/ | |
http://www.bitsavers.org/pdf/hp/2000TSB/ | |
http://www.bitsavers.org/pdf/hp/21xx/ | |
...and from the HP Computer Museum at: | |
http://www.hpmuseum.net/collection_document.php | |
---------------- | |
Year 2000 Issues | |
---------------- | |
RTE-6/VM Revision 6200 is Y2K compliant, except for the READR and SAVER | |
programs. The errors are cosmetic only. | |
RTE-IVB Revision 5010 is not Y2K compliant. All of the failures are in | |
subsystems; the operating itself (time-of-day clock) accommodates dates through | |
2059. All of the errors are cosmetic. Typically, punctuation characters appear | |
in the years, e.g., "19:0" for 2000. The RTE-IVB software kit from the HP | |
Computer Museum includes fixes for the affected modules to bring the system into | |
compliance. | |
All other HP operating systems are not Y2K compliant. | |
----------------------------- | |
Bugs in RTE-IVB Revision 5010 | |
----------------------------- | |
Testing during simulator development revealed the presence of a bug in RTE-IVB | |
Revision 5010: | |
- The $BALC module in the system library has a bug that causes memory | |
corruption. This module is used by the ACCTS program and manifests itself by | |
printing gibberish after the "PLEASE LOG ON:" prompt. | |
Specifically, the internal MXEV routine performs a cross-store indirect via a | |
location in Table Area II (XSA $MAXI+0,I). This fails because the indirect | |
chain is resolved in the user map, but TA II is not in the user map of | |
large-background programs, such as ACCTS. Therefore, the location in the | |
user map corresponding to $MAXI in the system map is used as the pointer to | |
the location to store. | |
A corrected version of $BALC is present on cartridge GF of the disc image | |
supplied with the RTE-IVB software kit at the HP Computer Museum. | |
====================== | |
Release 27, 2017-09-06 | |
====================== | |
This release of the HP 2100 simulator adds the following features: | |
- Support for the HP 2613, 2617, and 2618 line printers has been added to the | |
LPT device. The default printer remains the HP 2607. | |
- The LPT device simulation has been rewritten to support realistic and | |
optimized timing, compact and expanded output modes, custom VFU tape images, | |
and tracing of internal operations. | |
- The LOAD command has been rewritten to load files containing absolute binary | |
loaders into the protected address space of the 21xx machines and configure | |
the I/O instructions. For the 1000, LOAD can also be used to load boot | |
loader ROM images other than those provided directly by the simulator. | |
- The DUMP command has been added to write the binary loader currently resident | |
in memory to an absolute binary file. | |
- The TTY punch unit and the LPS, LPT, and PTP devices now position a newly | |
attached file at the end of the file rather than at the start. As a result, | |
output will append to, rather than overwrite, the existing content. | |
- The DA, DP, DQ, and DS disc devices add the PROTECT and UNPROTECT options. | |
These replace the now-deprecated LOCKED and WRITEENABLED options and more | |
accurately reflect the labelling of the data protection switches on the disc | |
drives. | |
- The simulator message that is displayed when a programmed halt occurs has | |
been changed to indicate that the halt code comes from the T-register value. | |
- The Basic Binary Loader (BBL) is now installed by default in the 21xx | |
machines. It is automatically configured to the select code of the paper | |
tape reader. It may be overwritten with a different loader (e.g., the Basic | |
Binary Disc Loader or Basic Moving-head Disc Loader) using the LOAD command. | |
Performing a power-on reset of the CPU reinstalls the BBL. | |
- Symbolic display and entry has been rewritten to improve efficiency and | |
expanded to cover the full instruction set including optional microcode | |
extensions that are currently enabled. | |
- CPU instruction execution and data accesses may be selectively traced. The | |
resulting trace listing is similar to the output of a logic analyzer | |
connected to the CPU and I/O buses. | |
- DMA/DCPC commands, status, and data accesses may be selectively traced. | |
- TBG commands, status, and service entries may be selectively traced. | |
- The DIAG option of the TBG device has been replaced with the REALTIME, W1A, | |
W1B, W2A, and W2B options. Configuring the TBG to run its diagnostic now | |
uses the REALTIME and W2B options, and restoring the normal configuration | |
uses the CALTIME and W2A options. The W1A and W1B options extend the | |
software compatibility of the TBG. | |
- The MUXM device has been renamed MUXC to reflect that it is the multiplexer | |
control card. The previous MUXM name is deprecated but will still work in | |
existing simulation command files. | |
- The multiplexer control card (MUXC) may be enabled and disabled independently | |
of the upper and lower data cards (MUX and MUXL), reflecting its optional | |
status in hardware configurations. | |
- Memory address parsing for commands has been changed to add <page>.<offset> | |
format for physical addresses, where both the page and the offset range from | |
0 to 1777 octal. Linear addressing is now restricted to the 32K logical | |
address space (0 to 77777 octal). Memory display uses linear addressing for | |
locations within the logical address space; locations above 32K use the | |
physical address format. | |
- The previously separate STOP_INST, STOP_DEV, STOP_IOE, and INDMAX | |
pseudo-registers used to stop the simulator under certain conditions have | |
been replaced by the SET CPU STOP=<stopname>[,<stopname>...] and the SET CPU | |
INDIR=<limit> commands. Stops may be temporarily bypassed by adding the -B | |
switch to the command that resumes execution. | |
- The HP 2100 Simulator User's Guide has been rewritten and significantly | |
expanded. | |
-------------------- | |
Implementation Notes | |
-------------------- | |
- The simulator passes the HP 2613/17/18 line printer diagnostic as described | |
in the "hp2100_diag.txt" file. | |
- The line printer terminates each print line with the HP-standard CR/LF pair. | |
If the output file is to be retained as a text file on a Unix system, removal | |
of the carriage returns, e.g., via the "dos2unix" utility, may be desirable. | |
- The LOAD command can no longer be used to read general absolute binary paper | |
tape images into memory. The ATTACH PTR and BOOT PTR commands must now be | |
used to read paper tapes. | |
- The OS, OSTBG, VMA, EMA, VIS, and SIGNAL CPU debug flags have been removed. | |
Tracing of these firmware instructions is now performed by specifying SET CPU | |
DEBUG=EXEC and SET CPU EXEC with the appropriate opcode range and mask, as | |
follows: | |
* SET CPU DEBUG=OS => SET CPU EXEC=105340;177760 | |
* SET CPU DEBUG=VMA => SET CPU EXEC=105240;177760 | |
* SET CPU DEBUG=EMA => SET CPU EXEC=105240;177760 | |
* SET CPU DEBUG=VIS => SET CPU EXEC=101460;173760 | |
* SET CPU DEBUG=SIGNAL => SET CPU EXEC=105600;177760 | |
- The separate tracing of time-base generator interrupt instructions provided | |
by the OS and OSTBG CPU debug flags is no longer supported. Entering the | |
replacement command above traces all OS instructions, including the TBG | |
interrupt instructions. | |
- The TIMER, RRR 16, .FLUN, and the OS/VMA, VIS, and SIGNAL self-test | |
instructions are no longer exempt from the undefined/unimplemented | |
instruction stop tests. Attempted execution of these instructions without | |
the appropriate firmware options installed will cause simulation stops if the | |
UNDEF (TIMER and RRR) or UNIMPL (.FLUN and self-tests) option is enabled. | |
Because of this change, the default state of the unimplemented instruction | |
stop has been reversed from "on" to "off". | |
- The "stop on I/O error" features controlled by the STOP_IOE register values | |
have been removed from the DR, LPS, LPT, MSC, MTC, and PTP devices, as all of | |
these report I/O error status to the CPU via their interface input registers. | |
STOP_IOE has been removed from the PTR device and replaced with SET CPU | |
STOP=IOERR, as this device does not report I/O error status to the CPU | |
through its interface. | |
- The LOCKED and WRITEENABLED options for the MSC and MTC devices are | |
deprecated. The supported method of write-protecting a tape drive is to | |
attach the tape image with the -R (read-only) switch or by setting the host | |
operating system's read-only attribute on the tape image file. This | |
simulates removing the write ring from the tape reel before mounting it on | |
the drive. There is no hardware method of write-protecting a mounted and | |
positioned tape reel. | |
- If the previous ATTACH behavior (overwriting rather than appending) is | |
desired for the TTY punch unit and the LPS, LPT, and PTP devices, set the | |
device's (P)POS register to 0 after attaching. | |
---------- | |
Bugs Fixed | |
---------- | |
1. PROBLEM: EXAMINE -M for addresses > 32K displays misleading operands. | |
VERSION: Release 26. | |
OBSERVATION: Current-page memory references of instructions residing above | |
the 32K logical address space are printed as though they reside at their | |
locations modulo 32K. For example, DEPOSIT 170001 026020 and EXAMINE -M | |
170001 displays JMP 70020, and DEPOSIT 200001 026020 displays JMP 20. | |
CAUSE: The printed addresses assume that the instructions will be executed | |
from their respective pages (modulo 32). However, instructions can be | |
executed only when they are mapped into the logical address space, and any | |
given physical page may be mapped to any arbitrary logical page. | |
Therefore, the address printed may not represent the actual logical address | |
after mapping. | |
RESOLUTION: Modify "fprint_cpu" (hp2100_sys.c) to use Z/C address notation | |
for memory references in instructions residing in physical memory above | |
32K. | |
STATUS: Fixed in Release 27. | |
2. PROBLEM: Enabling IOP firmware should not be allowed on the 1000 F-Series. | |
VERSION: Release 26. | |
OBSERVATION: The command "SET CPU 1000-F,IOP" is allowed, but it should | |
not be, as the IOP firmware is not supported on this machine. | |
CAUSE: The F-Series does not provide the firmware mapping table entries | |
that permit operation of the 2000/Access I/O Processor firmware. IOP | |
instruction opcodes 10x400-17 and 10x420-37 are marked as "HP Reserved" in | |
the F-Series mapping table, and opcodes 10x460-77 are dedicated to the VIS | |
microcode. | |
RESOLUTION: Modify the "cpu_features" array (hp2100_cpu.c) to remove the | |
IOP option from the 1000 F-Series entry. | |
STATUS: Fixed in Release 27. | |
3. PROBLEM: A rejected model change still changes the CPU options. | |
VERSION: Release 26. | |
OBSERVATION: Changing to a CPU model that does not support the current | |
memory size will reduce memory to the maximum supported by the new model. | |
If the truncated portion contains non-zero values, the simulator will ask | |
for confirmation before proceeding. If the truncation is rejected, the CPU | |
options are still set to those of the new model, even though the old model | |
is retained. For example: | |
sim> SET CPU 1000-F,128K | |
sim> SHOW CPU | |
CPU idle disabled | |
128KW, 1000-F, EAU | |
FP, no IOP, DMS | |
FFP, DBI, no EMA/VMA | |
no VIS, no SIGNAL | |
sim> DEPOSIT 100000 1 | |
sim> SET CPU 2116 | |
Really truncate memory [N]?NO | |
Command not completed | |
sim> SHOW CPU | |
CPU idle disabled | |
128KW, 1000-F, no EAU | |
no FP, no IOP, no DMS | |
no FFP, no DBI, no EMA/VMA | |
no VIS, no SIGNAL | |
CAUSE: The CPU options are set before the memory size is changed, so when | |
the size change is rejected, the new CPU options are retained. | |
RESOLUTION: Modify "cpu_set_model" (hp2100_cpu.c) to perform the memory | |
size change first, so that if it is rejected, the CPU options have not been | |
changed. | |
STATUS: Fixed in Release 27. | |
4. PROBLEM: Virtual memory mapping fails for accesses above 126 MB. | |
VERSION: Release 26. | |
OBSERVATION: A program using virtual memory provided by the RTE-6/VM | |
operating system may access up to 128 MB of data, although VMA programs | |
default to a 16 MB limit. Accesses to data in virtual memory are mapped | |
through the last two DMS user map registers. Normally, each VMA access | |
maps in the memory page corresponding to the virtual address plus the | |
following memory page. This allows access to single items up to 1024 words | |
in size starting at any offset within the (first) page. | |
If a data item resides in the last 2 MB of virtual memory, access to an | |
item that crosses the page boundary is incorrect. Instead of accessing | |
words in the second page, the accesses wrap around within the first page. | |
CAUSE: The suit number part of the virtual address is not restored before | |
checking the allocation status of the page table entry corresponding to the | |
second (spillover) page. As a result, an unallocated second page in the | |
last 2 MB of virtual memory is seen as beyond the VM area limit, and | |
instead of generating a page fault to allocate the second page, the map | |
registers are set up to prevent access to the second page by setting the | |
first page address into both map registers. | |
RESOLUTION: Modify "cpu_vma_lbp" (hp2100_cpu5.c) to check for spill page | |
allocation correctly. | |
STATUS: Fixed in Release 27. | |
5. PROBLEM: Memory expansion is not disabled when DMS is disabled. | |
VERSION: Release 26. | |
OBSERVATION: If the Memory Expansion Module in a 1000-Series CPU has been | |
enabled, and then the DMS firmware option is disabled or the CPU is changed | |
to a model that does not support memory expansion (e.g., a 2100), memory | |
expansion remains enabled. In this case, memory accesses should revert to | |
physical addressing, but instead logical-to-physical address translation | |
through the currently enabled map remains in effect. | |
CAUSE: Disabling DMS should set the "dms_enb" flag to 0, but it does not. | |
RESOLUTION: Modify "set_model" and "set_option" (hp2100_cpu.c) to clear | |
the "dms_enb" flag if DMS is not enabled after the model or option change. | |
STATUS: Fixed in Release 27. | |
====================== | |
Release 26, 2017-05-01 | |
====================== | |
This release of the HP 2100 simulator does not add any new features. | |
-------------------- | |
Implementation Notes | |
-------------------- | |
- Starting with the next release, the LOAD command will be rewritten to load | |
files containing absolute binary loaders into the protected address space of | |
the 21xx machines and configure the I/O instructions. The LOAD command is | |
not designed for general loading of absolute binary files, as it does not | |
initialize the A and B registers as some HP software expects. It is intended | |
only to install bootstrap loaders. The BOOT PTR command is the proper | |
simulation of the hardware absolute paper tape loader. | |
---------- | |
Bugs Fixed | |
---------- | |
1. PROBLEM: The RWCS debug option shown in the user's guide does not exist. | |
VERSION: Release 25. | |
OBSERVATION: The "HP2100 Simulator User's Guide" says that the RWCS debug | |
option may be specified for the DS and DA devices to trace "disk read/ | |
write/control/status commands." However, entering a SET DS DEBUG=RWCS | |
command gives an "Invalid argument" error. | |
CAUSE: The option name is misspelled; the correct option is RWSC. | |
RESOLUTION: Modify "hp2100_doc.doc" to list the correct option name. | |
STATUS: Fixed in Release 26. | |
2. PROBLEM: Halt opcodes 1060xx and 1070xx do not display in mnemonic form. | |
VERSION: Release 25. | |
OBSERVATION: Halt instructions 106000-106077 and 107000-107077 are not | |
displayed in mnemonic form, either directly with an EXAMINE -M command | |
or in the message displayed for a programmed halt. These instruction | |
ranges are displayed in octal only. | |
CAUSE: Section 3.20, "Input/Output Instructions," of the "HP 1000 | |
M/E/F-Series Computers Technical Reference Handbook" (HP 5955-0282, March | |
1980) says, in part, "Bit 11, where relevant, specifies the A- or | |
B-register or distinguishes between set control and clear control; | |
otherwise, bit 11 may be a logic 0 or a logic 1 without affecting the | |
instruction (although the assembler will assign zeros in this case)." The | |
HLT instruction does not specify the A/B register, so the valid opcodes are | |
102000-102077, 103000-103777, 106000-106077, and 107000-107077. However, | |
the latter two ranges are omitted from the "opcode" and "opc_val" tables | |
used for decoding. | |
RESOLUTION: Add the 1060xx/107xx range to the "opc_val" table and a second | |
"HLT" string to the "opcode" table (hp2100_sys.c) to permit mnemonic | |
display of this instruction range. | |
STATUS: Fixed in Release 26. | |
3. PROBLEM: The SFB (scan for byte) opcode displays as SBT (store byte). | |
VERSION: Release 25. | |
OBSERVATION: Entering the "EVAL -M 105767" command should display the | |
"SFB" mnemonic. Instead, it displays "SBT". | |
CAUSE: The entry in the opcode mnemonic table corresponding to the 105767 | |
value is "SBT", which is incorrect. It should be "SFB" (SBT is 105764). | |
RESOLUTION: Modify the "opcode" table (hp2100_sys.c) to use the correct | |
mnemonic for the SFB instruction. | |
STATUS: Fixed in Release 26. | |
4. PROBLEM: Host file system seek errors are not caught. | |
VERSION: Release 25. | |
OBSERVATION: The MAC/ICD disc library checks for host file system read or | |
write errors and returns Uncorrectable Data Error status if an error is | |
indicated. However, host file system seeks are simply assumed to succeed; | |
no indication of an error is given if a call fails. A failed seek should | |
be detected, and a Drive Fault (positioner error) should be returned. | |
CAUSE: Oversight. | |
RESOLUTION: Modify "position_sector" (hp2100_disclib.c) to test the | |
"sim_fseek" call for error status and to simulate a Drive Fault (AGC error) | |
if the call fails. | |
STATUS: Fixed in Release 26. | |
5. PROBLEM: Set Flow Control and Cancel commands fail if port key is not set. | |
VERSION: Release 25. | |
OBSERVATION: HP 8-channel multiplexer commands that refer to ports do so | |
indirectly by passing a port key, rather than a port number. The | |
key-to-port translation is established by the "Set Port Key" command, which | |
must be executed before any port-specific commands. If a port key has not | |
been established, then all port-specific commands should be ignored. | |
However, the "Cancel first receive buffer" and "Set flow control" commands | |
cause program corruption if the key has not been set. | |
CAUSE: The test for key validity is improperly applied for these commands. | |
RESOLUTION: Modify "exec_command" (hp2100_mpx.c) to ignore these commands | |
if the port key has not been set. | |
STATUS: Fixed in Release 26. | |
6. ENHANCEMENT: Improve the EAU shift and rotate instruction simulations. | |
VERSION: Release 25. | |
OBSERVATION: The shift and rotate instructions (ASL, ASR, LSL, LSR, RRL, | |
and RRR) perform 32-bit operations on the combined B and A registers. The | |
original implementation treated the 16-bit registers independently. | |
However, it is faster and smaller to form a 32-bit operand, apply the | |
operation, and then split the operand back into the B and A registers. | |
Modern compilers, such as gcc, recognize the shifting and masking patterns | |
necessary for a rotation and generate a single rotate-left or rotate-right | |
machine instruction. | |
RESOLUTION: Modify "cpu_eau" (hp2100_cpu1.c) to reimplement the shift and | |
rotate instructions as 32-bit operations. | |
STATUS: Fixed in Release 26. | |
====================== | |
Release 25, 2017-01-11 | |
====================== | |
This is the initial checkpoint release of the HP 2100 simulator, corresponding | |
to the 25th set of changes to the 4.0 code base. The following devices are | |
currently simulated: | |
- 2114C CPU with up to 16 KW of memory | |
- 2115A CPU with up to 8 KW of memory | |
- 2116C CPU with up to 32 KW of memory | |
- 2100A CPU with up to 32 KW of memory | |
- 1000 M/E/F-Series CPU with up to 1024 KW of memory | |
- EAU, FP, IOP, DMS, FFP, DBI, VIS, and SIGNAL microcode extensions | |
- RTE-IV EMA or RTE-6/VM OS and VMA microcode extensions | |
- 12531C Buffered Teleprinter Interface with one 2752 Teleprinter | |
- 12539C Time Base Generator | |
- 12557A Disc Controller with four 2870 drives | |
- 12559C Magnetic Tape Controller with one 3030 drive | |
- 12565A Disc Controller with two 2883 drives | |
- 12566B Microcircuit Interface with a loopback connector | |
- 12578A Direct Memory Access Controller | |
- 12581A Memory Protect | |
- 12597A Duplex Register Interface with one 2748 Paper Tape Reader | |
- 12597A Duplex Register Interface with one 2895 Paper Tape Punch | |
- 12606B Fixed Head Disc Controller with one 2770/2771 drive | |
- 12607B Direct Memory Access Controller | |
- 12610B Drum Controller with one 2773/2774/2775 drive | |
- 12620A Privileged Interrupt Fence | |
- 12653A Printer Controller with one 2767 Line Printer | |
- 12792C 8-Channel Asynchronous Multiplexer | |
- 12821A Disc Interface with four 7906H/7920H/7925H drives | |
- 12845B Printer Controller with one 2607 Line Printer | |
- 12875A Interprocessor Link | |
- 12892B Memory Protect | |
- 12895A Direct Memory Access Controller | |
- 12897B Dual-Channel Port Controller | |
- 12920A 16-Channel Terminal Multiplexer | |
- 12936A Privileged Interrupt Fence | |
- 12966A Buffered Asynchronous Communications Interface | |
- 13037D Disc Controller with eight 7905/7906/7920/7925 drives | |
- 13181A Magnetic Tape Controller with four 7970B drives | |
- 13183A Magnetic Tape Controller with four 7970E drives | |
- 13210A Disc Controller with four 7900 drives | |
The "HP 2100 Simulator User's Guide" manual describes the configuration and | |
operation of each of these devices in detail. | |
-------------------- | |
Implementation Notes | |
-------------------- | |
- New bug fixes will now be listed in this file under the associated release | |
rather than in their previous location (hp2100_bugfixes.txt). | |
- Starting with the next release, the LOAD command will restrict its operation | |
to the addresses occupied by the bootstrap loaders, i.e., the last 64 | |
locations in memory (up to 32K). The LOAD command is not designed for | |
general loading of absolute binary files, as it does not initialize the A and | |
B registers as some HP software expects. It is intended only to install | |
bootstrap loaders. The BOOT PTR command is the proper simulation of the | |
hardware absolute paper tape loader. | |
---------- | |
Bugs Fixed | |
---------- | |
1. PROBLEM: DPC device documentation uses the wrong disc drive model number. | |
VERSION: Release 24. | |
OBSERVATION: The comments in the hp2100_dpc.c source file and Section 2 of | |
the "HP2100 Simulator User's Guide" say that the DPC device supports the | |
2871 disc drive, while Section 2.6.1 of the User's Guide says that the | |
support is for the 2781 disc drive. Neither of these model numbers is | |
correct. | |
Contemporaneous literature (e.g., the "2116B Computer Price List," dated | |
June 1970) states that the disc memory subsystem consists of the HP 2870A | |
Moving Head Disc, HP 2871A Disc Controller, HP 2881A Power Supply, and HP | |
2882A Cabinet. | |
CAUSE: The controller model number is used instead of the drive model | |
number, while the "2781" number is a transposition of "2871." | |
RESOLUTION: Modify the initial comments in the DPC device source file | |
(hp2100_dpc.c) and modify the sections of the HP2100 Simulator User's Guide | |
to use the correct disc drive model number (2870). | |
STATUS: Fixed in Release 25. | |
2. PROBLEM: The BOOT DRC command does not execute correctly. | |
VERSION: Release 24. | |
OBSERVATION: Attempting to boot DOS from a fixed-head disc or drum does | |
not work. The CPU sits in a loop waiting for DMA to finish, but it never | |
does. | |
CAUSE: The DMA control word in the DR device bootstrap is not configured | |
during BOOT DRC processing, so DMA is communicating with the wrong device. | |
RESOLUTION: Modify "drc_boot" (hp2100_dr.c) to set the fixed disc/drum | |
select code into the DMA control word before returning. | |
STATUS: Fixed in Release 25. | |
3. PROBLEM: The valid command "DEPOSIT 2000 JMP 2001" is rejected. | |
VERSION: Release 24. | |
OBSERVATION: Regarding symbolic input, the HP2100 User's Manual says that | |
the "C" and "Z" flags, signifying a current-page or zero-page reference, | |
respectively, are not needed "...when entering [memory reference] | |
instructions into CPU memory; the simulator figures out from the target | |
address what mode to use." While the valid command "DEPOSIT 1000 JMP 1001" | |
correctly enters a zero-page jump into memory, the valid command "DEPOSIT | |
2000 JMP 2001" does not enter a current-page jump. Instead, an "Invalid | |
argument" error occurs. | |
CAUSE: The "parse_sym" routine looks for the optional "C" or "Z" flag when | |
parsing memory reference instructions and sets a flag if either is | |
specified. The test for a current-page reference is performed only if the | |
reference type was not explicitly specified. However, the sense of the | |
test is reversed. | |
RESOLUTION: Modify "parse_sym" (hp2100_sys.c) to correct the test for C/Z | |
option specification. | |
STATUS: Fixed in Release 25. | |
4. PROBLEM: The invalid command "DEPOSIT 2000 JMP C 2001" is accepted. | |
VERSION: Release 24. | |
OBSERVATION: Regarding symbolic input, the HP2100 User's Manual says that | |
"The address is an octal number in the range 0 - 77777; if C or Z is | |
specified, the address is a page offset in the range 0 - 1777." However, | |
specifying a page offset > 1777 is accepted without complaint if it is | |
within the current page range. | |
CAUSE: Error checking for memory reference instruction entry is | |
incomplete. | |
RESOLUTION: Modify "parse_sym" (hp2100_sys.c) to ensure that the range | |
check is enforced if either C or Z is specified. | |
STATUS: Fixed in Release 25. | |
5. PROBLEM: Punched output does not appear on TTY devices lacking a paper | |
tape punch. | |
VERSION: Release 24. | |
OBSERVATION: Running the HP contributed library program "HP 2000F BASIC | |
for DOS-M/DOS III" does not produce any console output when using terminal | |
driver DVR00 as required by the program. When using alternate terminal | |
driver DVR05, console output appears but console input does not work | |
properly. | |
CAUSE: DOS-M and DOS-III support two modes of console I/O: ASCII mode and | |
binary mode. ASCII mode appends carriage-return/line-feed characters on | |
output and strips them on input. Binary mode sends and receives bytes | |
exactly as supplied. | |
DVR00 is required because DVR05 does not support the binary I/O mode | |
required by the program. However, DVR00 assumes that a binary write is to | |
be directed to the console's paper tape punch rather than the console | |
printer and therefore sets the TTY interface's "punch flip-flop" instead of | |
the "print flip-flop" to accompany the text output. The simulation of the | |
HP 12531 interface card associated with the TTY device discards output if | |
the punch flip-flop is set and the punch unit (TTY2) is not attached. | |
The problem occurs because only a connected HP 2754 teleprinter (a modified | |
Teletype ASR35) reacts to the print and punch flip-flop signals. All other | |
supported terminal devices ignore the signals and print whatever output is | |
supplied (an HP 2752 -- a rebadged ASR33 -- has a manual control for the | |
punch, but the punch and printer operate together when the punch is on). | |
The 2000F BASIC program apparently was designed for use with one of these | |
other terminals, which print normally even though only the punch flip-flop | |
is set. | |
RESOLUTION: Modify "tto_out" (hp2100_stddev.c) to honor the print and | |
punch flip-flop settings and separate the output as directed only if the | |
console punch unit is attached (simulating an HP 2754). When the unit is | |
detached, all output is delivered to the console printer, regardless of the | |
flip-flop settings (simulating all other console devices). | |
STATUS: Fixed in Release 25. |