To: Users | |
From: Bob Supnik | |
Subj: PDP-11 Simulator Usage | |
Date: 15-Sep-2003 | |
COPYRIGHT NOTICE | |
The following copyright notice applies to both the SIMH source and binary: | |
Original code published in 1993-2003, written by Robert M Supnik | |
Copyright (c) 1993-2003, Robert M Supnik | |
Permission is hereby granted, free of charge, to any person obtaining a | |
copy of this software and associated documentation files (the "Software"), | |
to deal in the Software without restriction, including without limitation | |
the rights to use, copy, modify, merge, publish, distribute, sublicense, | |
and/or sell copies of the Software, and to permit persons to whom the | |
Software is furnished to do so, subject to the following conditions: | |
The above copyright notice and this permission notice shall be included in | |
all copies or substantial portions of the Software. | |
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR | |
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, | |
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL | |
ROBERT M SUPNIK BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER | |
IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN | |
CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE. | |
Except as contained in this notice, the name of Robert M Supnik shall not | |
be used in advertising or otherwise to promote the sale, use or other dealings | |
in this Software without prior written authorization from Robert M Supnik. | |
This memorandum documents the PDP-11 simulator. | |
1. Simulator Files | |
To compile the PDP-11, you must define VM_PDP11 as part of the compilation | |
command line. If you want expanded file support, you must also define USE_INT64 | |
and USE_ADDR64 as part of the compilation command line. | |
sim/ sim_defs.h | |
sim_ether.h | |
sim_rev.h | |
sim_sock.h | |
sim_tape.h | |
sim_tmxr.h | |
scp.c | |
scp_tty.c | |
sim_ether.c | |
sim_sock.c | |
sim_tape.c | |
sim_tmxr.c | |
sim/pdp11/ pdp11_defs.h | |
pdp11_mscp.h | |
pdp11_uqssp.h | |
pdp11_xq.h | |
pdp11_xq_bootrom.h | |
pdp11_cpu.c | |
pdp11_dz.c | |
pdp11_fp.c | |
pdp11_hk.c | |
pdp11_io.c | |
pdp11_lp.c | |
pdp11_pclk.c | |
pdp11_pt.c | |
pdp11_rk.c | |
pdp11_rl.c | |
pdp11_rp.c | |
pdp11_rq.c | |
pdp11_tq.c | |
pdp11_rx.c | |
pdp11_ry.c | |
pdp11_stddev.c | |
pdp11_sys.c | |
pdp11_tc.c | |
pdp11_tm.c | |
pdp11_ts.c | |
pdp11_xq.c | |
pdp11_xu.c | |
2. PDP-11 Features | |
The PDP-11 simulator is configured as follows: | |
device simulates | |
name(s) | |
CPU J-11 CPU with 256KB of memory | |
- FP11 floating point unit (FPA) | |
- CIS11 commercial instruction set (CIS, off by default) | |
PTR,PTP PC11 paper tape reader/punch | |
TTI,TTO DL11 console terminal | |
LPT LP11 line printer | |
CLK line frequency clock | |
PCLK KW11P programmable clock | |
DZ DZ11 8-line terminal multiplexor (up to 4) | |
RK RK11/RK05 cartridge disk controller with eight drives | |
HK RK611/RK06(7) cartridge disk controller with eight drives | |
RL RLV12/RL01(2) cartridge disk controller with four drives | |
RP RM02/03/05/80, RP04/05/06/07 Massbus style controller | |
with eight drives | |
RQ RQDX3 MSCP controller with four drives | |
RQB second RQDX3 MSCP controller with four drives | |
RQC third RQDX3 MSCP controller with four drives | |
RQD fourth RQDX3 MSCP controller with four drives | |
RX RX11/RX01 floppy disk controller with two drives | |
RY RX211/RX01 floppy disk controller with two drives | |
TC TC11/TU56 DECtape controller with eight drives | |
TM TM11/TU10 magnetic tape controller with eight drives | |
TS TS11/TSV05 magnetic tape controller with one drive | |
TQ TQK50 TMSCP magnetic tape controller with four drives | |
XQ DELQA/DEQNA Qbus Ethernet controller | |
XQB second DELQA/DEQNA Qbus Ethernet controller | |
XU DEUNA/DELUA Unibus Ethernet controller | |
The DZ, RK, HK, RL, RP, RQ, RQB, RQC, RQD, RX, RY, TC, TM, TS, TQ, XQ, XQB, | |
and XU devices can be set DISABLED. RQB, RQC, RQD, RY, TS, XQB, and XU are | |
disabled by default. | |
The PDP-11 simulator implements several unique stop conditions: | |
- abort during exception vector fetch, and register STOP_VEC is set | |
- abort during exception stack push, and register STOP_SPA is set | |
- trap condition 'n' occurs, and register STOP_TRAP<n> is set | |
- wait state entered, and no I/O operations outstanding | |
(ie, no interrupt can ever occur) | |
The PDP-11 loader supports standard binary format tapes. The DUMP command | |
is not implemented. | |
2.1 CPU | |
The CPU options include CPU mapping configuration (18b Unibus, 22b Unibus | |
with RH70-style controllers, 22b Unibus with RH11 style controllers, and | |
22b Qbus), the CIS instruction set, and the size of main memory. | |
SET CPU 18B 18b addressing, no I/O map | |
SET CPU URH11 22b addresssing, Unibus I/O map, | |
18b mapped RH11 controller | |
SET CPU URH70 22b addressing, Unibus I/O map, | |
22b unmapped RH70 controller | |
SET CPU 22B 22b addressing, no I/O map (Qbus) | |
SET CPU NOCIS disable CIS instructions (default) | |
SET CPU CIS enable CIS instructions | |
SET CPU 16K set memory size = 16KB | |
SET CPU 32K set memory size = 32KB | |
SET CPU 48K set memory size = 48KB | |
SET CPU 64K set memory size = 64KB | |
SET CPU 96K set memory size = 96KB | |
SET CPU 128K set memory size = 128KB | |
SET CPU 192K set memory size = 192KB | |
SET CPU 256K set memory size = 256KB | |
SET CPU 384K set memory size = 384KB | |
SET CPU 512K set memory size = 512KB | |
SET CPU 768K set memory size = 768KB | |
SET CPU 1024K (or 1M) set memory size = 1024KB | |
SET CPU 2048K (or 2M) set memory size = 2048KB | |
SET CPU 3072K (or 3M) set memory size = 3072KB | |
SET CPU 4096K (or 4M) set memory size = 4096KB | |
The CPU implements a show command to display the I/O address space map: | |
SHOW CPU IOSPACE show I/O space address map | |
If memory size is being reduced, and the memory being truncated contains | |
non-zero data, the simulator asks for confirmation. Data in the truncated | |
portion of memory is lost. Initial memory size is 256KB. If memory size | |
is being increased to more than 256KB, or the bus structue is being changed, | |
the simulator asks whether it should disable peripherals that can't run | |
in the current bus structure. | |
DMA peripherals function differently, depending on whether the CPU is | |
configured for 18B, URH11, URH70, or 22B addressing and I/O: | |
peripheral 18B URH11 URH70 22B | |
RK 18b 18b 18b won't work, disabled | |
HK 18b 18b 18b SC02/C 22b, works | |
only with Ultrix-11 | |
RL 18b 18b 18b 22b RLV12 | |
RP 18b 18b 22b 22b third party | |
RQ 18b 18b 18b 22b RQDX3 | |
RY 18b 18b 18b won't work, disabled | |
TC 18b 18b 18b won't work, disabled | |
TM 18b 18b 18b won't work, disabled | |
TS 18b 18b 18b 22b TSV05 | |
TQ 18b 18b 18b 22b TQK50 | |
XQ 18b won't work, 22b DELQA | |
disabled | |
XU 18b 18b 18b won't work, disabled | |
Non-DMA peripherals work the same in all configurations. Unibus-only | |
peripherals should be disabled in a Qbus (22B) configuration with more | |
than 256KB of memory, and Qbus-only peripherals should be disabled in | |
a Unibus (URH11 or URH70) configuration with more than 256KB of memory. | |
These switches are recognized when examining or depositing in CPU memory: | |
-v interpret address as virtual | |
-d if mem mgt enabled, force data space | |
-k if mem mgt enabled, force kernel mode | |
-s if mem mgt enabled, force supervisor mode | |
-u if mem mgt enabled, force user mode | |
-p if mem mgt enabled, force previous mode | |
CPU registers include the visible state of the processor as well as the | |
control registers for the interrupt system. | |
name size comments | |
PC 16 program counter | |
R0..R5 16 R0..R5, current register set | |
SP 16 stack pointer, current mode | |
R00..R05 16 R0..R5, register set 0 | |
R10..R15 16 R0..R5, register set 1 | |
KSP 16 kernel stack pointer | |
SSP 16 supervisor stack pointer | |
USP 16 user stack pointer | |
PSW 16 processor status word | |
CM 2 current mode, PSW<15:14> | |
PM 2 previous mode, PSW<13:12> | |
RS 2 register set, PSW<11> | |
IPL 3 interrupt priority level, PSW<7:5> | |
T 1 trace bit, PSW<4> | |
N 1 negative flag, PSW<3> | |
Z 1 zero flag, PSW<2> | |
V 1 overflow flag, PSW<1> | |
C 1 carry flag, PSW<0> | |
SR 16 front panel switches | |
DR 16 front panel display | |
MEMERR 16 memory error register | |
CCR 16 cache control register | |
MAINT 16 maintenance register | |
HITMISS 16 hit/miss register | |
CPUERR 16 CPU error register | |
PIRQ 16 programmed interrupt requests | |
FAC0H..FAC5H 32 FAC0..FAC5, high 32 bits | |
FAC0L..FAC5L 32 FAC0..FAC5, low 32 bits | |
FPS 16 floating point status | |
FEA 16 floating exception address | |
FEC 4 floating exception code | |
MMR0..3 16 memory management registers 0..3 | |
{K/S/U}{I/D}{PAR/PDR}{0..7} | |
16 memory management registers | |
UBMAP[0:63] 16 Unibus map registers | |
INT 32 interrupt pending flags | |
TRAP 18 trap pending flags | |
WAIT 0 wait state flag | |
WAIT_ENABLE 0 wait state enable flag | |
STOP_TRAPS 18 stop on trap flags | |
STOP_VECA 1 stop on read abort in trap or interrupt | |
STOP_SPA 1 stop on stack push abort in trap or interrupt | |
PCQ[0:63] 16 PC prior to last jump, branch, or interrupt; | |
most recent PC change first | |
WRU 8 interrupt character | |
2.2 I/O Device Addressing | |
PDP-11 I/O space is not large enough to allow all possible devices to be | |
configured simultaneously at fixed addresses. Instead, many devices have | |
floating addresses; that is, the assigned device address depends on the | |
presense of other devices in the configuration: | |
DZ11 all instances have floating addresses | |
RL11 first instance has fixed address, rest floating | |
RX11/RX211 first instance has fixed address, rest floating | |
DEUNA/DELUA first instance has fixed address, rest floating | |
MSCP disk first instance has fixed address, rest floating | |
TMSCP tape first instance has fixed address, rest floating | |
To maintain addressing consistency as the configuration changes, the | |
simulator implements DEC's standard I/O address and vector autoconfiguration | |
algorithms for devices DZ, RL, RX, RY, XU, RQ, and TQ. This allows the | |
user to enable or disable devices without needing to manage I/O addresses | |
and vectors. For example, if RY is enabled while RX is present, RY is | |
assigned an I/O address in the floating I/O space range; but if RX is | |
disabled and then RY is enabled, RY is assigned the fixed "first instance" | |
I/O address for floppy disks. | |
Autoconfiguration cannot solve address conflicts between devices with | |
overlapping fixed addresses. For example, with default I/O page addressing, | |
the PDP-11 can support either a TM11 or a TS11, but not both, since they use | |
the same I/O addresses. | |
In addition to autoconfiguration, most devices support the SET ADDRESS | |
command, which allows the I/O page address of the device to be changed, | |
and the SET VECTOR command, which allows the vector of the device to be | |
changed. Explicitly setting the I/O address of a device which normally | |
uses autoconfiguration DISABLES autoconfiguration for that device. As | |
a consequence, the user may have to manually configure all other | |
autoconfigured devices, because the autoconfiguration algorithm no | |
longer recognizes the explicitly configured device. A device can be | |
reset to autoconfigure with the SET <device> AUTOCONFIGURE command. | |
The current I/O map can be displayed with the SHOW CPU IOSPACE command. | |
Addresses that have set by autoconfiguration are marked with an asterisk (*). | |
All devices support the SHOW ADDRESS and SHOW VECTOR commands, which display | |
the device address and vector, respectively. | |
2.3 Programmed I/O Devices | |
2.3.1 PC11 Paper Tape Reader (PTR) | |
The paper tape reader (PTR) reads data from a disk file. The POS | |
register specifies the number of the next data item to be read. Thus, | |
by changing POS, the user can backspace or advance the reader. | |
The paper tape reader implements these registers: | |
name size comments | |
BUF 8 last data item processed | |
CSR 16 control/status register | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
BUSY 1 busy flag (CSR<11>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
POS 32 position in the input file | |
TIME 24 time from I/O initiation to interrupt | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 out of tape | |
end of file 1 report error and stop | |
0 out of tape | |
OS I/O error x report error and stop | |
2.3.2 PC11 Paper Tape Punch (PTP) | |
The paper tape punch (PTP) writes data to a disk file. The POS | |
register specifies the number of the next data item to be written. | |
Thus, by by changing POS, the user can backspace or advance the punch. | |
The paper tape punch implements these registers: | |
name size comments | |
BUF 8 last data item processed | |
CSR 16 control/status register | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
POS 32 position in the output file | |
TIME 24 time from I/O initiation to interrupt | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 out of tape | |
OS I/O error x report error and stop | |
2.3.3 DL11 Terminal Input (TTI) | |
The terminal interfaces (TTI, TTO) can be set to one of two modes: | |
7B or 8B. In 7B mode, input and output characters are masked to 7 | |
bits. In 8B mode, characters are not modified. Changing the mode | |
of either interface changes both. The default mode is 8B. | |
The terminal input (TTI) polls the console keyboard for input. It | |
implements these registers: | |
name size comments | |
BUF 8 last data item processed | |
CSR 16 control/status register | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
POS 32 number of characters input | |
TIME 24 keyboard polling interval | |
If the simulator is compiled under Windows Visual C++, typing ^C to the | |
terminal input causes a fatal run-time error. Use the following command | |
to simulate typing ^C: | |
SET TTI CTRL-C | |
2.3.4 DL11 Terminal Output (TTO) | |
The terminal output (TTO) writes to the simulator console window. It | |
implements these registers: | |
name size comments | |
BUF 8 last data item processed | |
CSR 16 control/status register | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
POS 32 number of characters input | |
TIME 24 time from I/O initiation to interrupt | |
2.3.5 LP11 Line Printer (LPT) | |
The line printer (LPT) writes data to a disk file. The POS register | |
specifies the number of the next data item to be written. Thus, | |
by changing POS, the user can backspace or advance the printer. | |
The line printer implements these registers: | |
name size comments | |
BUF 8 last data item processed | |
CSR 16 control/status register | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
POS 32 position in the output file | |
TIME 24 time from I/O initiation to interrupt | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 out of paper | |
OS I/O error x report error and stop | |
2.3.6 Line-Time Clock (CLK) | |
The line-time clock (CLK) frequency can be adjusted as follows: | |
SET CLK 60HZ set frequency to 60Hz | |
SET CLK 50HZ set frequency to 50Hz | |
The default is 60Hz. | |
The line-time clock implements these registers: | |
name size comments | |
CSR 16 control/status register | |
INT 1 interrupt pending flag | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
TIME 24 clock interval | |
The line-time clock autocalibrates; the clock interval is adjusted up | |
or down so that the clock tracks actual elapsed time. | |
2.3.7 Programmable Clock (PCLK) | |
The programmable clock (PCLK) line frequency can be adjusted as follows: | |
SET PCLK 60HZ set frequency to 60Hz | |
SET PCLK 50HZ set frequency to 50Hz | |
The default is 60Hz. | |
The programmable clock implements these registers: | |
name size comments | |
CSR 16 control/status register | |
CSB 16 count set buffer | |
CNT 16 current count | |
INT 1 interrupt pending flag | |
OVFL 1 overflow (error) flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
UPDN 1 up/down count mode (CSR<4>) | |
MODE 1 single/repeat mode (CSR<3>) | |
RUN 1 clock run (CSR<0>) | |
TIME[0..3] 32 clock interval, rates 0..3 | |
TPS[0..3] 32 ticks per second, rates 0..3 | |
The programmable clock autocalibrates; the clock interval is adjusted | |
up or down so that the clock tracks actual elapsed time. Operation at | |
the highest clock rate (100Khz) is not recommended. The programmable | |
clock is disabled by default. | |
2.3.8 DZ11 Terminal Multiplexor (DZ) | |
The DZ11 is an 8-line terminal multiplexor. Up to 4 DZ11's (32 lines) | |
are supported. The number of lines can be changed with the command | |
SET DZ LINES=n set line count to n | |
The line count must be a multiple of 8, with a maximum of 32. | |
The DZ11 supports 8-bit input and output of characters. 8-bit output | |
may be incompatible with certain operating systems. The command | |
SET DZ 7B | |
forces output characters (only) to be masked to 7 bits. | |
The terminal lines perform input and output through Telnet sessions | |
connected to a user-specified port. The ATTACH command specifies | |
the port to be used: | |
ATTACH {-am} DZ <port> set up listening port | |
where port is a decimal number between 1 and 65535 that is not being used | |
for other TCP/IP activities. The optional switch -m turns on the DZ11's | |
modem controls; the optional switch -a turns on active disconnects | |
(disconnect session if computer clears Data Terminal Ready). Without | |
modem control, the DZ behaves as though terminals were directly connected; | |
disconnecting the Telnet session does not cause any operating system- | |
visible change in line status. | |
Once the DZ is attached and the simulator is running, the DZ will listen | |
for connections on the specified port. It assumes that the incoming | |
connections are Telnet connections. The connection remains open until | |
disconnected by the simulated program, the Telnet client, a SET DZ | |
DISCONNECT command, or a DETACH DZ command. | |
The SHOW DZ CONNECTIONS command displays the current connections to the DZ. | |
The SHOW DZ STATISTICS command displays statistics for active connections. | |
The SET DZ DISCONNECT=linenumber disconnects the specified line. | |
The DZ11 implements these registers: | |
name size comments | |
CSR[0:3] 16 control/status register, boards 0..3 | |
RBUF[0:3] 16 receive buffer, boards 0..3 | |
LPR[0:3] 16 line parameter register, boards 0..3 | |
TCR[0:3] 16 transmission control register, boards 0..3 | |
MSR[0:3] 16 modem status register, boards 0..3 | |
TDR[0:3] 16 transmit data register, boards 0..3 | |
SAENB[0:3] 1 silo alarm enabled, boards 0..3 | |
RXINT 4 receive interrupts, boards 3..0 | |
TXINT 4 transmit interrupts, boards 3..0 | |
MDMTCL 1 modem control enabled | |
AUTODS 1 autodisconnect enabled | |
The DZ11 does not support save and restore. All open connections are | |
lost when the simulator shuts down or the DZ is detached. | |
2.4 Floppy Disk Drives | |
2.4.1 RX11/RX01 Floppy Disk (RX) | |
RX11 options include the ability to set units write enabled or write locked: | |
SET RXn LOCKED set unit n write locked | |
SET RXn WRITEENABLED set unit n write enabled | |
The RX11 supports the BOOT command. | |
The RX11 implements these registers: | |
name size comments | |
RXCS 12 status | |
RXDB 8 data buffer | |
RXES 8 error status | |
RXERR 8 error code | |
RXTA 8 current track | |
RXSA 8 current sector | |
STAPTR 3 controller state | |
BUFPTR 3 buffer pointer | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
TR 1 transfer ready flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
DONE 1 device done flag (CSR<5>) | |
CTIME 24 command completion time | |
STIME 24 seek time, per track | |
XTIME 24 transfer ready delay | |
STOP_IOE 1 stop on I/O error | |
SBUF[0:127] 8 sector buffer array | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 disk not ready | |
RX01 data files are buffered in memory; therefore, end of file and OS | |
I/O errors cannot occur. | |
2.4.2 RX211/RX02 Floppy Disk (RY) | |
RX211 options include the ability to set units write enabled or write | |
locked, single or double density, or autosized: | |
SET RYn LOCKED set unit n write locked | |
SET RYn WRITEENABLED set unit n write enabled | |
SET RYn SINGLE set unit n single density | |
SET RYn DOUBLE set unit n double density (default) | |
SET RYn AUTOSIZE set unit n autosized | |
The RX211 supports the BOOT command. The RX211 will not function | |
properly in a Qbus (22B) system with more than 256KB of memory. | |
The RX211 implements these registers: | |
name size comments | |
RYCS 16 status | |
RYBA 16 buffer address | |
RYWC 8 word count | |
RYDB 16 data buffer | |
RYES 12 error status | |
RYERR 8 error code | |
RYTA 8 current track | |
RYSA 8 current sector | |
STAPTR 4 controller state | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
TR 1 transfer ready flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
DONE 1 device done flag (CSR<5>) | |
CTIME 24 command completion time | |
STIME 24 seek time, per track | |
XTIME 24 transfer ready delay | |
STOP_IOE 1 stop on I/O error | |
SBUF[0:255] 8 sector buffer array | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 disk not ready | |
RX02 data files are buffered in memory; therefore, end of file and OS | |
I/O errors cannot occur. | |
2.5 Cartridge Disk Drives | |
2.5.1 RK11/RK05 Cartridge Disk (RK) | |
RK11 options include the ability to make units write enabled or write | |
locked: | |
SET RKn LOCKED set unit n write locked | |
SET RKn WRITEENABLED set unit n write enabled | |
Units can also be set ONLINE or OFFLINE. The RK11 supports the BOOT | |
command. The RK11 will not function properly in a Qbus (22B) system | |
with more than 256KB of memory. | |
The RK11 implements these registers: | |
name size comments | |
RKCS 16 control/status | |
RKDA 16 disk address | |
RKBA 16 memory address | |
RKWC 16 word count | |
RKDS 16 drive status | |
RKER 16 error status | |
INTQ 9 interrupt queue | |
DRVN 3 number of last selected drive | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
INT 1 interrupt pending flag | |
STIME 24 seek time, per cylinder | |
RTIME 24 rotational delay | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 disk not ready | |
end of file x assume rest of disk is zero | |
OS I/O error x report error and stop | |
2.5.2 RK611/RK06,RK07 Cartridge Disk (HK) | |
RK611 options include the ability to set units write enabled or write | |
locked, to set the drive size to RK06, RK07, or autosize, and to write | |
a DEC standard 044 compliant bad block table on the last track: | |
SET HKn LOCKED set unit n write locked | |
SET HKn WRITEENABLED set unit n write enabled | |
SET HKn RK06 set size to RK06 | |
SET HKn RK07 set size to RK07 | |
SET HKn AUTOSIZE set size based on file size at attach | |
SET HKn BADBLOCK write bad block table on last track | |
The size options can be used only when a unit is not attached to a file. | |
The bad block option can be used only when a unit is attached to a file. | |
Units can be set ONLINE or OFFLINE. The RK611 supports the BOOT command. | |
The RK611 will not function properly in a Qbus (22B) system with more | |
than 256KB of memory using standard DEC software. The simulator implements | |
a third-party extension of addressing capability to 22b; this is only | |
supported by Ultrix-11. | |
The RK611 implements these registers: | |
name size comments | |
HKCS1 16 control/status 1 | |
HKWC 16 word count | |
HKBA 16 bus address | |
HKDA 16 desired surface, sector | |
HKCS2 16 control/status 2 | |
HKDS[0:7] 16 drive status, drives 0-7 | |
HKER[0:7] 16 drive errors, drives 0-7 | |
HKDB[0:2] 16 data buffer silo | |
HKDC 16 desired cylinder | |
HKOF 8 offset | |
HKMR 16 maintenance register | |
HKSPR 16 spare register | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR1<7>) | |
IE 1 interrupt enable flag (CSR1<6>) | |
STIME 24 seek time, per cylinder | |
RTIME 24 rotational delay | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 disk not ready | |
end of file x assume rest of disk is zero | |
OS I/O error x report error and stop | |
2.5.3 RL11(V12)/RL01,RL02 Cartridge Disk (RL) | |
RL11 options include the ability to set units write enabled or write | |
locked, to set the drive size to RL01, RL02, or autosize, and to write | |
a DEC standard 044 compliant bad block table on the last track: | |
SET RLn LOCKED set unit n write locked | |
SET RLn WRITEENABLED set unit n write enabled | |
SET RLn RL01 set size to RL01 | |
SET RLn RL02 set size to RL02 | |
SET RLn AUTOSIZE set size based on file size at attach | |
SET RLn BADBLOCK write bad block table on last track | |
The size options can be used only when a unit is not attached to a file. | |
The bad block option can be used only when a unit is attached to a file. | |
Units can be set ONLINE or OFFLINE. The RL11 supports the BOOT command. | |
In an 18B or Unibus system, the RL behaves like an RL11 with 18b | |
addressing; in a Qbus (22B) system, the RL behaves like the RLV12 with | |
22b addressing. | |
The RL11 implements these registers: | |
name size comments | |
RLCS 16 control/status | |
RLDA 16 disk address | |
RLBA 16 memory address | |
RLBAE 6 memory address extension (RLV12) | |
RLMP..RLMP2 16 multipurpose register queue | |
INT 1 interrupt pending flag | |
ERR 1 error flag (CSR<15>) | |
DONE 1 device done flag (CSR<7>) | |
IE 1 interrupt enable flag (CSR<6>) | |
STIME 24 seek time, per cylinder | |
RTIME 24 rotational delay | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 disk not ready | |
end of file x assume rest of disk is zero | |
OS I/O error x report error and stop | |
2.6 RM02/03/05/80, RP04/05/06/07 Disk Pack Drives (RP) | |
The RP controller implements a "Massbus style" 22b direct interface | |
for large disk drives. It is more abstract than other device simulators, | |
with just enough detail to run operating system drivers. In addition, | |
the RP controller conflates the details of the RM series controllers | |
with the RP series controllers, although there were detailed differences. | |
RP options include the ability to set units write enabled or write | |
locked, to set the drive type to one of six disk types, or autosize, | |
and to write a DEC standard 044 compliant bad block table on the last | |
track: | |
SET RPn LOCKED set unit n write locked | |
SET RPn WRITEENABLED set unit n write enabled | |
SET RPn RM03 set type to RM03 | |
SET RPn RM05 set type to RM05 | |
SET RPn RM80 set type to RM80 | |
SET RPn RP04 set type to RP04 | |
SET RPn RP06 set type to RP06 | |
SET RPn RP07 set type to RP07 | |
SET RPn AUTOSIZE set type based on file size at attach | |
SET RPn BADBLOCK write bad block table on last track | |
The type options can be used only when a unit is not attached to a file. | |
The bad block option can be used only when a unit is attached to a file. | |
Units can be set ONLINE or OFFLINE. The RP controller supports the | |
BOOT command. In a Unibus system, the RP can implement either 18b | |
(RH11) addressing or 22b (RH70) addressing. In a Qbus (22B) system, | |
the RP always implements 22b addressing. | |
The RP controller implements these registers: | |
name size comments | |
RPCS1 16 control/status 1 | |
RPWC 16 word count | |
RPBA 16 bus address | |
RPDA 16 desired surface, sector | |
RPCS2 16 control/status 2 | |
RPDS[0:7] 16 drive status, drives 0-7 | |
RPER1[0:7] 16 drive errors, drives 0-7 | |
RPOF 16 offset | |
RPDC 16 desired cylinder | |
RPER2 16 error status 2 | |
RPER3 16 error status 3 | |
RPEC1 16 ECC syndrome 1 | |
RPEC2 16 ECC syndrome 2 | |
RPMR 16 maintenance register | |
RPDB 16 data buffer | |
RPBAE 6 bus address extension | |
RPCS3 16 control/status 3 | |
IFF 1 transfer complete interrupt request flop | |
INT 1 interrupt pending flag | |
SC 1 special condition (CSR1<15>) | |
DONE 1 device done flag (CSR1<7>) | |
IE 1 interrupt enable flag (CSR1<6>) | |
STIME 24 seek time, per cylinder | |
RTIME 24 rotational delay | |
STOP_IOE 1 stop on I/O error | |
Error handling is as follows: | |
error STOP_IOE processed as | |
not attached 1 report error and stop | |
0 disk not ready | |
end of file x assume rest of disk is zero | |
OS I/O error x report error and stop | |
2.7 RQDX3 MSCP Disk Controllers (RQ, RQB, RQC, RQD) | |
The simulator implements four MSCP disk controllers, RQ, RQB, RQC, RQD. | |
Initially, RQB, RQC, and RQD are disabled. Each RQ controller simulates | |
an RQDX3 MSCP disk controller. RQ options include the ability to set | |
units write enabled or write locked, and to set the drive type to one | |
of many disk types: | |
SET RQn LOCKED set unit n write locked | |
SET RQn WRITEENABLED set unit n write enabled | |
SET RQn RX50 set type to RX50 | |
SET RQn RX33 set type to RX33 | |
SET RQn RD51 set type to RD51 | |
SET RQn RD52 set type to RD52 | |
SET RQn RD53 set type to RD53 | |
SET RQn RD54 set type to RD54 | |
SET RQn RD31 set type to RD31 | |
SET RQn RA82 set type to RA82 | |
SET RQn RA72 set type to RA72 | |
SET RQn RA90 set type to RA90 | |
SET RQn RA92 set type to RA92 | |
SET RQn RRD40 set type to RRD40 (CD ROM) | |
SET RQn RAUSER{=n} set type to RA81 with n LBNs | |
The type options can be used only when a unit is not attached to a file. | |
RAUSER is a "user specified" disk; the user can specify the size of the | |
disk in logical block numbers (LBN's, 512 bytes each). The minimum size | |
is 50MB; the maximum size is 2GB. | |
Units can also be set ONLINE or OFFLINE. Each RQ controller supports the | |
BOOT command. In a Unibus system, an RQ supports 18b addressing. In | |
a Qbus (22B) system, an RQ supports 22b addressing. | |
Each RQ controller implements the following special SHOW commands: | |
SHOW RQn TYPE show drive type | |
SHOW RQ RINGS show command and response rings | |
SHOW RQ FREEQ show packet free queue | |
SHOW RQ RESPQ show packet response queue | |
SHOW RQ UNITQ show unit queues | |
SHOW RQ ALL show all ring and queue state | |
SHOW RQn UNITQ show unit queues for unit n | |
Each RQ controller implements these registers: | |
name size comments | |
SA 16 status/address register | |
S1DAT 16 step 1 init host data | |
CQBA 22 command queue base address | |
CQLNT 8 command queue length | |
CQIDX 8 command queue index | |
RQBA 22 request queue base address | |
RQLNT 8 request queue length | |
RQIDX 8 request queue index | |
FREE 5 head of free packet list | |
RESP 5 head of response packet list | |
PBSY 5 number of busy packets | |
CFLGS 16 controller flags | |
CSTA 4 controller state | |
PERR 9 port error number | |
CRED 5 host credits | |
HAT 17 host available timer | |
HTMO 17 host timeout value | |
CPKT[0:3] 5 current packet, units 0-3 | |
PKTQ[0:3] 5 packet queue, units 0-3 | |
UFLG[0:3] 16 unit flags, units 0-3 | |
INT 1 interrupt request | |
ITIME 1 response time for initialization steps | |
(except for step 4) | |
QTIME 24 response time for 'immediate' packets | |
XTIME 24 response time for data transfers | |
PKTS[33*32] 16 packet buffers, 33W each, | |
32 entries | |
Some DEC operating systems, notably RSX11M/M+, are very sensitive to | |
the timing parameters. Changing the default values may cause M/M+ to | |
crash on boot or to hang during operation. | |
Error handling is as follows: | |
error processed as | |
not attached disk not ready | |
end of file assume rest of disk is zero | |
OS I/O error report error and stop | |
2.8 TC11/TU56 DECtape (DT) | |
DECtapes drives are numbered 1-8; in the simulator, drive 8 is unit 0. | |
DECtape options include the ability to make units write enabled or write | |
locked. | |
SET DTn LOCKED set unit n write locked | |
SET DTn WRITEENABLED set unit n write enabled | |
Units can be set ONLINE or OFFLINE. The TC11 supports the BOOT command. | |
The TC11 will not function properly in a 22B (Qbus) system with more | |
than 256KB of memory. | |
The TC11 supports supports PDP-8 format, PDP-11 format, and 18b format | |
DECtape images. ATTACH tries to determine the tape format from the DECtape | |
image; the user can force a particular format with switches: | |
-r PDP-8 format | |
-s PDP-11 format | |
-t 18b format | |
The DECtape controller is a data-only simulator; the timing and mark | |
track, and block header and trailer, are not stored. Thus, the WRITE | |
TIMING AND MARK TRACK function is not supported; the READ ALL function | |
always returns the hardware standard block header and trailer; and the | |
WRITE ALL function dumps non-data words into the bit bucket. | |
The TC controller implements these registers: | |
name size comments | |
TCST 16 status register | |
TCCM 16 command register | |
TCWC 16 word count register | |
TCBA 16 bus address register | |
TCDT 16 data register | |
INT 1 interrupt pending flag | |
ERR 1 error flag | |
DONE 1 done flag | |
IE 1 interrupt enable flag | |
CTIME 31 time to complete transport stop | |
LTIME 31 time between lines | |
ACTIME 31 time to accelerate to full speed | |
DCTIME 31 time to decelerate to a full stop | |
SUBSTATE 2 read/write command substate | |
POS[0:7] 32 position, in lines, units 0-7 | |
STATT[0-7] 31 unit state, units 0-7 | |
It is critically important to maintain certain timing relationships | |
among the DECtape parameters, or the DECtape simulator will fail to | |
operate correctly. | |
- LTIME must be at least 6 | |
- ACTIME must be less than DCTIME, and both need to be at | |
least 100 times LTIME | |
2.9 Magnetic Tape Controllers | |
2.9.1 TM11 Magnetic Tape (TM) | |
TM options include the ability to make units write enabled or write | |
locked. | |
SET TMn LOCKED set unit n write locked | |
SET TMn WRITEENABLED set unit n write enabled | |
Units can be set ONLINE or OFFLINE. | |
The TM11 supports the BOOT command. The bootstrap supports both original | |
and DEC standard boot formats. Originally, a tape bootstrap read and | |
executed the first record on tape. To allow for ANSI labels, the DEC | |
standard bootstrap skipped the first record and read and executed the | |
second. The DEC standard is the default; to bootstrap an original format | |
tape, use the -o switch. | |
The TM11 will not function properly in a Qbus (22B) system with more | |
than 256KB of memory | |
The TM controller implements these registers: | |
name size comments | |
MTS 16 status | |
MTC 16 command | |
MTCMA 16 memory address | |
MTBRC 16 byte/record count | |
INT 1 interrupt pending flag | |
ERR 1 error flag | |
DONE 1 device done flag | |
IE 1 interrupt enable flag | |
STOP_IOE 1 stop on I/O error | |
TIME 24 delay | |
UST[0:7] 16 unit status, units 0-7 | |
POS[0:7] 32 position, units 0-7 | |
Error handling is as follows: | |
error processed as | |
not attached tape not ready; if STOP_IOE, stop | |
end of file bad tape | |
OS I/O error parity error; if STOP_IOE, stop | |
2.9.2 TS11/TSV05 Magnetic Tape (TS) | |
The TS actually implements the TSV05, with 22-bit addressing, but will | |
work with TS11 drivers. TS options include the ability to make the unit | |
write enabled or write locked. | |
SET TS LOCKED set unit write locked | |
SET TS WRITEENABLED set unit write enabled | |
The TS11 supports the BOOT command. The bootstrap supports only DEC | |
standard boot formats. To allow for ANSI labels, the DEC standard | |
bootstrap skipped the first record and read and executed the second. | |
In a Unibus system, the TS behaves like the TS11 and implements 18b | |
addresses. In a Qbus (22B) system, the TS behaves like the TSV05 | |
and implements 22b addresses. | |
The TS controller implements these registers: | |
name size comments | |
TSSR 16 status register | |
TSBA 16 bus address register | |
TSDBX 16 data buffer extension register | |
CHDR 16 command packet header | |
CADL 16 command packet low address or count | |
CADH 16 command packet high address | |
CLNT 16 command packet length | |
MHDR 16 message packet header | |
MRFC 16 message packet residual frame count | |
MXS0 16 message packet extended status 0 | |
MXS1 16 message packet extended status 1 | |
MXS2 16 message packet extended status 2 | |
MXS3 16 message packet extended status 3 | |
MXS4 16 message packet extended status 4 | |
WADL 16 write char packet low address | |
WADH 16 write char packet high address | |
WLNT 16 write char packet length | |
WOPT 16 write char packet options | |
WXOPT 16 write char packet extended options | |
ATTN 1 attention message pending | |
BOOT 1 boot request pending | |
OWNC 1 if set, tape owns command buffer | |
OWNM 1 if set, tape owns message buffer | |
TIME 24 delay | |
POS 32 position | |
Error handling is as follows: | |
error processed as | |
not attached tape not ready | |
end of file bad tape | |
OS I/O error fatal tape error | |
2.9.3 TQK50 TMSCP Disk Controller (TQ) | |
The TQ controller simulates the TQK50 TMSCP disk controller. TQ options | |
include the ability to set units write enabled or write locked, and to | |
specify the controller type and tape length: | |
SET TQn LOCKED set unit n write locked | |
SET TQn WRITEENABLED set unit n write enabled | |
SET TQ TK50 set controller type to TK50 | |
SET TQ TK70 set controller type to TK70 | |
SET TQ TU81 set controller type to TU81 | |
SET TQ TKUSER{=n} set controller type to TK50 with | |
tape capacity of n MB | |
User-specified capacity must be between 50 and 2000 MB. | |
The TQ controller supports the BOOT command. In a Unibus system, the | |
TQ supports 18b addressing. In a Qbus (22B) system, the TQ supports | |
22b addressing. | |
The TQ controller implements the following special SHOW commands: | |
SHOW TQ TYPE show controller type | |
SHOW TQ RINGS show command and response rings | |
SHOW TQ FREEQ show packet free queue | |
SHOW TQ RESPQ show packet response queue | |
SHOW TQ UNITQ show unit queues | |
SHOW TQ ALL show all ring and queue state | |
SHOW TQn UNITQ show unit queues for unit n | |
The TQ controller implements these registers: | |
name size comments | |
SA 16 status/address register | |
S1DAT 16 step 1 init host data | |
CQBA 22 command queue base address | |
CQLNT 8 command queue length | |
CQIDX 8 command queue index | |
RQBA 22 request queue base address | |
RQLNT 8 request queue length | |
RQIDX 8 request queue index | |
FREE 5 head of free packet list | |
RESP 5 head of response packet list | |
PBSY 5 number of busy packets | |
CFLGS 16 controller flags | |
CSTA 4 controller state | |
PERR 9 port error number | |
CRED 5 host credits | |
HAT 17 host available timer | |
HTMO 17 host timeout value | |
CPKT[0:3] 5 current packet, units 0-3 | |
PKTQ[0:3] 5 packet queue, units 0-3 | |
UFLG[0:3] 16 unit flags, units 0-3 | |
POS[0:3] 32 tape position, units 0-3 | |
OBJP[0:3] 32 object position, units 0-3 | |
INT 1 interrupt request | |
ITIME 1 response time for initialization steps | |
(except for step 4) | |
QTIME 24 response time for 'immediate' packets | |
XTIME 24 response time for data transfers | |
PKTS[33*32] 16 packet buffers, 33W each, | |
32 entries | |
Some DEC operating systems, notably RSX11M/M+, are very sensitive to | |
the timing parameters. Changing the default values may cause M/M+ to | |
crash on boot or to hang during operation. | |
Error handling is as follows: | |
error processed as | |
not attached tape not ready | |
end of file end of medium | |
OS I/O error fatal tape error | |
2.10 DELQA/DEQNA Qbus Ethernet Controllers (XQ, XQB) | |
The simulator implements two DELQA/DEQNA Qbus Ethernet controllers (XQ, | |
XQB). Initially, XQ is enabled, and XQB is disabled. Options allow | |
control of the MAC address, the controller mode, and the sanity timer. | |
SET XQ MAC=<mac-address> ex. 08-00-2B-AA-BB-CC | |
SHOW XQ MAC | |
These commands are used to change or display the MAC address. <mac-address> | |
is a valid ethernet MAC, delimited by dashes or periods. The controller | |
defaults to 08-00-2B-AA-BB-CC, which should be sufficient if there is | |
only one SIMH controller on your LAN. Two cards with the same MAC address | |
will see each other's packets, resulting in a serious mess. | |
SET XQ TYPE={DEQNA|[DELQA]} | |
SHOW XQ TYPE | |
These commands are used to change or display the controller mode. DELQA | |
mode is better and faster but may not be usable by older or non-DEC OS's. | |
Also, be aware that DEQNA mode is not supported by many modern OS's. The | |
DEQNA-LOCK mode of the DELQA card is emulated by setting the the controller | |
to DEQNA - there is no need for a separate mode. DEQNA-LOCK mode behaves | |
exactly like a DEQNA, except for the operation of the VAR and MOP processing. | |
SET XQ SANITY={ON|[OFF]} | |
SHOW XQ SANITY | |
These commands change or display the INITIALIZATION sanity timer (DEQNA | |
jumper W3/DELQA switch S4). The INITIALIZATION sanity timer has a default | |
timeout of 4 minutes, and cannot be turned off, just reset. The normal | |
sanity timer can be set by operating system software regardless of the | |
state of this switch. Note that only the DEQNA (or the DELQA in DEQNA- | |
LOCK mode (=DEQNA)) supports the sanity timer - it is ignored by a DELQA | |
in Normal mode, which uses switch S4 for a different purpose. | |
To access the network, the simulated Ethernet controller must be attached | |
to a real Ethernet interface: | |
ATTACH XQ0 {ethX|<device_name>} ex. eth0 or /dev/era0 | |
SHOW XQ ETH | |
where X in 'ethX' is the number of the ethernet controller to attach, or | |
the real device name. The X number is system dependant. If you only have | |
one ethernet controller, the number will probably be 0. To find out what | |
your system thinks the ethernet numbers are, use the SHOW XQ ETH command. | |
The device list can be quite cryptic, depending on the host system, but | |
is probably better than guessing. If you do not attach the device, the | |
controller will behave as though the ethernet cable were unplugged. | |
XQ has the following registers: | |
name size comments | |
SA0 16 station address word 0 | |
SA1 16 station address word 1 | |
SA2 16 station address word 2 | |
SA3 16 station address word 3 | |
SA4 16 station address word 4 | |
SA5 16 station address word 5 | |
CSR 16 control status register | |
VAR 16 vector address register | |
RBDL 32 receive buffer descriptor list | |
XBDL 32 trans(X)mit buffer descriptorlList | |
One final note: because of it's asynchronous nature, the XQ controller is | |
not limited to the ~1.5Mbit/sec of the real DEQNA/DELQA controllers, | |
nor the 10Mbit/sec of a standard Ethernet. Attach it to a Fast Ethernet | |
(100 Mbit/sec) card, and "Feel the Power!" :-) | |
2.11 DEUNA/DELUA Unibus Ethernet Controller (XU) | |
XU simulates the DEUNA/DELUA Unibus Ethernet controller. THe current | |
implementation is a stub and is permanently disabled. | |
2.12 Symbolic Display and Input | |
The PDP-11 simulator implements symbolic display and input. Display is | |
controlled by command line switches: | |
-a display as ASCII character | |
-c display as two character ASCII string | |
-m display instruction mnemonics | |
Input parsing is controlled by the first character typed in or by command | |
line switches: | |
' or -a ASCII character | |
" or -c two character ASCII string | |
alphabetic instruction mnemonic | |
numeric octal number | |
Instruction input uses standard PDP-11 assembler syntax. There are sixteen | |
instruction classes: | |
class operands examples comments | |
no operands none HALT, RESET | |
3b literal literal, 0 - 7 SPL | |
6b literal literal, 0 - 077 MARK | |
8b literal literal, 0 - 0377 EMT, TRAP | |
register register RTS | |
sop specifier SWAB, CLR, ASL | |
reg-sop register, specifier JSR, XOR, MUL | |
fop flt specifier ABSf, NEGf | |
ac-fop flt reg, flt specifier LDf, MULf | |
ac-sop flt reg, specifier LDEXP, STEXP | |
ac-moded sop flt reg, specifier LDCif, STCfi | |
dop specifier, specifier MOV, ADD, BIC | |
cond branch address BR, BCC, BNE | |
sob register, address SOB | |
cc clear cc clear instructions CLC, CLV, CLZ, CLN combinable | |
cc set cc set instructions SEC, SEV, SEZ, SEN combinable | |
For floating point opcodes, F and D variants, and I and L variants, may be | |
specified regardless of the state of FPS. | |
The syntax for specifiers is as follows: | |
syntax specifier displacement comments | |
Rn 0n - | |
Fn 0n - only in flt reg classes | |
(Rn) 1n - | |
@(Rn) 7n 0 equivalent to @0(Rn) | |
(Rn)+ 2n - | |
@(Rn)+ 3n - | |
-(Rn) 4n - | |
@-(Rn) 5n - | |
{+/-}d(Rn) 6n {+/-}d | |
@{+/-}d(Rn) 7n {+/-}d | |
#n 27 n | |
@#n 37 n | |
.+/-n 67 +/-n - 4 | |
@.+/-n 77 +/-n - 4 | |
{+/-}n 67 {+/-}n - PC - 4 if on disk, 37 and n | |
@{+/-}n 77 {+/-}n - PC - 4 if on disk, invalid |