blob: b3abbd31439b8ff93f7f9ca4686e0e5107bf98fb [file] [log] [blame] [raw]
To: Users
From: Bob Supnik
Subj: VAX780 Simulator Usage
Date: 01-Dec-2005
COPYRIGHT NOTICE
The following copyright notice applies to both the SIMH source and binary:
Original code published in 1993-2005, written by Robert M Supnik
Copyright (c) 1993-2005, Robert M Supnik
Permission is hereby granted, free of charge, to any person obtaining a
copy of this software and associated documentation files (the "Software"),
to deal in the Software without restriction, including without limitation
the rights to use, copy, modify, merge, publish, distribute, sublicense,
and/or sell copies of the Software, and to permit persons to whom the
Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in
all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL
ROBERT M SUPNIK BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER
IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN
CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
Except as contained in this notice, the name of Robert M Supnik shall not be
used in advertising or otherwise to promote the sale, use or other dealings
in this Software without prior written authorization from Robert M Supnik.
This memorandum documents the VAX simulator.
1. Simulator Files
To compile the VAX780, you must define VM_VAX, VAX780, and USE_INT64 as part of
the compilation command line. To enable extended file support (files greater
than 2GB), you must define USE_ADDR64 as part of the command line as well.
sim/ scp.h
sim_console.h
sim_defs.h
sim_ether.h
sim_fio.h
sim_rev.h
sim_sock.h
sim_tape.h
sim_timer.h
sim_tmxr.h
scp.c
sim_console.c
sim_ether.c
sim_fio.c
sim_sock.c
sim_tape.c
sim_timer.c
sim_tmxr.c
sim/vax/ vax_defs.h
vax780_defs.h
vax_cis.c
vax_cmode.c
vax_cpu.c
vax_cpu1.c
vax_fpa.c
vax_mmu.c
vax_octa.c
vax_sys.c
vax_syscm.c
vax780_mba.c
vax780_mem.c
vax780_sbi.c
vax780_stddev.c
vax780_syslist.c
vax780_uba.c
sim/pdp11/ pdp11_mscp.h
pdp11_uqssp.h
pdp11_xu.h
pdp11_dz.c
pdp11_hk.c
pdp11_lp.c
pdp11_rl.c
pdp11_rp.c
pdp11_rq.c
pdp11_ry.c
pdp11_tq.c
pdp11_ts.c
pdp11_tu.c
pdp11_xu.c
Additional files are:
sim/vax/ vmb780.bin standard boot code
2. VAX780 Features
The VAX simulator is configured as follows:
device simulates
name(s)
CPU VAX-11/780 CPU
TLB translation buffer
SBI system bus controller
MCTL0,MTCL1 memory controllers, MS780C with 4MB memory each, or
MS780E with 8MB-64MB each
UBA DW780 Unibus adapter
MBA0,MBA1 RH780 Massbus adapters
TODR time-of-day clock
TMR interval timer
TTI,TTO console terminal
RX console floppy
DZ DZ11 8-line terminal multiplexor (up to 4)
LPT LP11 line printer
RP RP04/RP05/RP06/RM03/RM05/RP07/RM80 Massbus disks, up to eight
HK RK611/RK06(7) cartridge disk controller with eight drives
RL RL11/RL01(2) cartridge disk controller with four drives
RQ UDA50 MSCP controller with four drives
RQB second UDA50 MSCP controller with four drives
RQC third UDA50 MSCP controller with four drives
RQD fourth UDA50 MSCP controller with four drives
RY RX211 floppy disk controller with two drives
TS TS11 magnetic tape controller with one drive
TQ TUK50 TMSCP magnetic tape controller with four drives
TU TM02/TM03 tape formatter with eight drives
XU DEUNA/DELUA Ethernet controller
XUB second DEUNA/DELUA Ethernet controller
The DZ, LPT, RP, RL, RQ, RQB, RQC, RQD, RY, TS, TQ, TU, XU, and XUB
devices can be set DISABLED. RQB, RQC, RQD, and XUB are disabled by
default.
The VAX780 simulator implements several unique stop conditions:
- change mode to interrupt stack
- illegal vector (bits<1:0> = 2 or 3)
- unexpected exception during interrupt or exception
- process PTE in P0 or P1 space instead of system space
- unknown IPL
- infinite loop (BRB/W to self at IPL 1F)
The VAX780 supports a simple binary format consisting of a stream of
binary bytes without origin or checksum, for loading memory.
2.1 CPU and System Devices
2.1.1 CPU
CPU options include the size of main memory and the treatment of the
HALT instruction.
SET CPU 8M set memory size = 8MB
SET CPU 16M set memory size = 16MB
SET CPU 32M set memory size = 32MB
SET CPU 48M set memory size = 48MB
SET CPU 64M set memory size = 64MB
SET CPU 128M set memory size = 128MB
The CPU implements a show command to display the I/O address map:
SHOW CPU IOSPACE show I/O space address map
The CPU also implements a command to display a virtual to physical address
translation:
SHOW CPU VIRTUAL=n show translation for address n
Notes on memory size:
- The first version of the VAX-11/780 used MS780C controllers, which
supported 1-4MB of memory per controller. This is the only memory
controller recognized by VMS V1.
- MS780E controllers supported 4MB-64MB per controller.
- The controller type is set automatically based on memory size.
Initial memory size is 8MB.
Memory can be loaded with a binary byte stream using the LOAD command.
The LOAD command recognizes three switches:
-o origin argument follows file name
-r load ROM in memory controller 0
-s load ROM in memory controller 1
These switches are recognized when examining or depositing in CPU memory
(or any other byte oriented device):
-b examine/deposit bytes
-w examine/deposit words
-l examine/deposit longwords
-d data radix is decimal
-o data radix is octal
-h data radix is hexadecimal
These switches are recognized when examining or depositing in CPU memory
only:
-m examine (only) VAX instructions
-p examine/deposit PDP-11 (compatibility mode)
instructions
-r examine (only) RADIX50 encoded data
-v interpret address as virtual, current mode
CPU registers include the visible state of the processor as well as the
control registers for the interrupt system.
name size comments
PC 32 program counter
R0..R14 32 R0..R14
AP 32 alias for R12
FP 32 alias for R13
SP 32 alias for R14
PSL 32 processor status longword
CC 4 condition codes, PSL<3:0>
KSP 32 kernel stack pointer
ESP 32 executive stack pointer
SSP 32 supervisor stack pointer
USP 32 user stack pointer
IS 32 interrupt stack pointer
SCBB 32 system control block base
PCBB 32 process controll block base
P0BR 32 P0 base register
P0LR 22 P0 length register
P1BR 32 P1 base register
P1LR 22 P1 length register
SBR 32 system base register
SLR 22 system length register
SISR 16 software interrupt summary register
ASTLVL 4 AST level register
MAPEN 1 memory management enable flag
TRPIRQ 8 trap/interrupt pending
CRDERR 1 correctible read data error flag
MEMERR 1 memory error flag
PCQ[0:63] 32 PC prior to last PC change or interrupt;
most recent PC change first
WRU 8 interrupt character
The CPU can maintain a history of the most recently executed instructions.
This is controlled by the SET CPU HISTORY and SHOW CPU HISTORY commands:
SET CPU HISTORY clear history buffer
SET CPU HISTORY=0 disable history
SET CPU HISTORY=n enable history, length = n
SHOW CPU HISTORY print CPU history
SHOW CPU HISTORY=n print first n entries of CPU history
The maximum length for the history is 65536 entries.
2.1.2 Translation Buffer (TLB)
The translation buffer consists of two units, representing the system
and user translation buffers, respectively. It has no registers. Each
translation buffer entry consists of two 32b words, as follows:
word n tag
word n+1 cached PTE
An invalid entry is indicated by a tag of FFFFFFFF.
2.1.3 SBI Controller (SBI)
The SBI was the VAX-11/780 system bus. The simulated SBI implements
these registers:
name size comments
NREQ14 16 Nexus IPL14 interrupt requests
NREQ15 16 Nexus IPL15 interrupt requests
NREQ16 16 Nexus IPL16 interrupt requests
NREQ17 16 Nexus IPL17 interrupt requests
WCSA 16 writeable control store address
WCSD 32 writeable control store data
MBRK 13 microbreak register
SBIFS 32 SBI fault status
SBISC 32 SBI silo compare
SBIMT 32 SBI maintenance register
SBIER 32 SBI error status
SBITMO 32 SBI timeout address
2.1.4 Memory Controllers (MCTL0, MCTL1)
The memory controllers implement the registers for the MS780C (non-
extended memory) or MS780E (extended memory). Each controller implements
these registers:
name size comments
CRA 32 control register A
CRB 32 control register B
CRC 32 control register C
CRD 32 control register D (MS780E only)
ROM[0:1023] 32 bootstrap ROM
ROM can be loaded from a file with the commands
LOAD -R <file> load MCTL0 ROM
LOAD -S <file> load MCTL1 ROM
2.1.5 Time-Of-Day Clock (TODR)
The TODR tracks time since an arbitrary start in 1 usec intervals. It
has these registers:
name size comments
TODR 32 time-of-day register
TIME 24 delay between ticks
The TODR register autocalibrates against real-world time.
2.1.6 Interval Timer (TMR)
The interval timer implements the VAX architectural timer, with 1 usec
intervals. It has these registers:
name size comments
ICCS 32 interval timer control and status
ICR 32 interval count register
NICR 32 next interval count register
INT 1 interrupt request
For standard VMS intervals (10msec = 100Hz), the interval timer
autocalibrates against real-world time.
2.1.7 Unibus Adapter (UBA)
The Unibus adapter (UBA) simulates the DW780. It recognizes these options:
SET UBA AUTOCONFIGURE enable autoconfiguration
SET UBA NOAUTOCONFIGURE disable autoconfiguration
and this display command:
SHOW UBA IOSPACE display IO address space assignments
The UBA has these registers:
name size comments
IPL14 32 Unibus IPL14 interrupt requests
IPL15 32 Unibus IPL15 interrupt requests
IPL16 32 Unibus IPL16 interrupt requests
IPL17 32 Unibus IPL17 interrupt requests
CNFR 32 configuration register
CR 32 control register
SR 32 status register
DR 32 diagnostic register
INT 1 internal UBA interrupt request
NEXINT 1 UBA Nexus interrupt request
AIIP 1 adapter initialization in progress flag
UIIP 1 Unibus initialization in progress flag
FMER 32 failing memory address
FUBAR 32 failing UBA map register
BRSVR0 32 spare register 0
BRSVR1 32 spare register 1
BRSVR2 32 spare register 2
BRSVR3 32 spare register 3
BRRVR4 32 vector register, IPL 14
BRRVR5 32 vector register, IPL 15
BRRVR6 32 vector register, IPL 16
BRRVR7 32 vector register, IPL 17
DPR[0:15] 32 data path registers 0..15
MAP[0:495] 32 map registers 0..495
AITIME 24 adapter initialization time
UITIME 24 Unibus initialization time
2.1.8 Massbus Adapters (MBA0, MBA1)
The Massbus adapters (MBA0, MBA1) simulate RH780's. MBA0 is assigned
to the RP disk drives, MBA1 to the TU tape drives. Each MBA has
these registers:
name size comments
CNFR 32 configuration register
CR 32 control register
SR 32 status register
VA 17 virtual address register
BC 32 byte count register
DR 32 diagnostic register
SMR 32 selected map register
MAP[0:255] 32 map registers
NEXINT 1 MBA Nexus interrupt request
2.2 I/O Device Addressing
Unibus I/O space is not large enough to allow all possible devices to be
configured simultaneously at fixed addresses. Instead, many devices have
floating addresses; that is, the assigned device address depends on the
presense of other devices in the configuration:
DZ11 all instances have floating addresses
RL11 first instance has fixed address, rest floating
RX11/RX211 first instance has fixed address, rest floating
DEUNA/DELUA first instance has fixed address, rest floating
MSCP disk first instance has fixed address, rest floating
TMSCP tape first instance has fixed address, rest floating
To maintain addressing consistency as the configuration changes, the
simulator implements DEC's standard I/O address and vector autoconfiguration
algorithms for devices DZ, VH, RL, RY, XUn, RQn, and TQ. This allows the
user to enable or disable devices without needing to manage I/O addresses
and vectors.
In addition to autoconfiguration, most devices support the SET ADDRESS
command, which allows the I/O page address of the device to be changed,
and the SET VECTOR command, which allows the vector of the device to be
changed. Explicitly setting the I/O address of a device which normally
uses autoconfiguration DISABLES autoconfiguration for that device and for
the entire system. As a consequence, the user may have to manually configure
all other autoconfigured devices, because the autoconfiguration algorithm
no longer recognizes the explicitly configured device. A device can be
reset to autoconfigure with the SET <device> AUTOCONFIGURE command. Auto-
configuration can be restored for the entire system with the SET UBA
AUTOCONFIGURE command.
The current I/O addresses can be displayed with the SHOW UBA IOSPACE command.
Addresses that have set by autoconfiguration are marked with an asterisk (*).
All devices support the SHOW ADDRESS and SHOW VECTOR commands, which display
the device address and vector, respectively.
2.3 Programmed I/O Devices
2.3.1 Console Input (TTI)
The console interfaces (TTI, TTO) can be set to one of three modes,
7P, 7B or 8B:
mode input characters output characters
7P high-order bit cleared high-order bit cleared,
non-printing characters
suppressed
7B high-order bit cleared high-order bit cleared
8B no changes no changes
The default mode is 8B.
The console input (TTI) polls the console keyboard for input. It
implements these registers:
name size comments
BUF 8 last data item processed
CSR 16 control/status register
INT 1 interrupt pending flag
ERR 1 error flag (CSR<15>)
DONE 1 device done flag (CSR<7>)
IE 1 interrupt enable flag (CSR<6>)
POS 32 number of characters input
TIME 24 keyboard polling interval
2.3.2 Console Output (TTO)
The console output (TTO) writes to the simulator console window. It
implements these registers:
name size comments
BUF 8 last data item processed
CSR 16 control/status register
INT 1 interrupt pending flag
ERR 1 error flag (CSR<15>)
DONE 1 device done flag (CSR<7>)
IE 1 interrupt enable flag (CSR<6>)
POS 32 number of characters input
TIME 24 time from I/O initiation to interrupt
2.3.3 RX01 Console Floppy Disk (RX)
RX01 options include the ability to set units write enabled or write
locked:
SET RXn LOCKED set unit n write locked
SET RXn WRITEENABLED set unit n write enabled
The RX01 implements these registers:
name size comments
FNC 8 function select
ES 8 error status
ECODE 8 error code
TA 8 track address
SA 8 sector address
STATE 4 protocol state
BPTR 7 data buffer pointer
CTIME 24 command initiation delay
STIME 24 seek time delay, per track
XTIME 24 transfer time delay, per byte
STOP_IOE 1 stop on I/O error
DBUF[0:127] 8 data buffer
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 disk not ready
RX01 data files are buffered in memory; therefore, end of file and OS
I/O errors cannot occur.
2.3.4 Line Printer (LPT)
The line printer (LPT) writes data to a disk file. The POS register
specifies the number of the next data item to be written. Thus,
by changing POS, the user can backspace or advance the printer.
The line printer implements these registers:
name size comments
BUF 8 last data item processed
CSR 16 control/status register
INT 1 interrupt pending flag
ERR 1 error flag (CSR<15>)
DONE 1 device done flag (CSR<7>)
IE 1 interrupt enable flag (CSR<6>)
POS 32 position in the output file
TIME 24 time from I/O initiation to interrupt
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 out of paper
OS I/O error x report error and stop
2.4 Disks
All VAX-11/780 disks support a special form of the boot command, with
the following syntax:
BOOT <unit>{/R5:<value>}
For example,
BOOT HK0/R5:1
The optional switch, /R5, specifies that R5 is to be loaded with the
specified value prior to booting. If the switch is omitted, R5 is loaded
with 0.
2.4.1 RM02/03/05/80, RP04/05/06/07 Disk Pack Drives (RP)
The RP controller implements the Massbus family of large disk drives.
RP options include the ability to set units write enabled or write
locked, to set the drive type to one of six disk types, or autosize,
and to write a DEC standard 044 compliant bad block table on the last
track:
SET RPn LOCKED set unit n write locked
SET RPn WRITEENABLED set unit n write enabled
SET RPn RM03 set type to RM03
SET RPn RM05 set type to RM05
SET RPn RM80 set type to RM80
SET RPn RP04 set type to RP04
SET RPn RP06 set type to RP06
SET RPn RP07 set type to RP07
SET RPn AUTOSIZE set type based on file size at attach
SET RPn BADBLOCK write bad block table on last track
The type options can be used only when a unit is not attached to a file.
The bad block option can be used only when a unit is attached to a file.
Units can be set ENABLED or DISABLED. The RP controller supports the
BOOT command.
The RP controller implements the registers listed below. Registers
suffixed with [0:7] are replicated per drive.
name size comments
CS1[0:7] 16 current operation
DA[0:7] 16 desired surface, sector
DS[0:7] 16 drive status
ER1[0:7] 16 drive errors
OF[0:7] 16 offset
DC[0:7] 16 desired cylinder
ER2[0:7] 16 error status 2
ER3[0:7] 16 error status 3
EC1[0:7] 16 ECC syndrome 1
EC2[0:7] 16 ECC syndrome 2
MR[0:7] 16 maintenance register
MR2[0:7] 16 maintenance register 2 (RM only)
HR[0:7] 16 holding register (RM only)
STIME 24 seek time, per cylinder
RTIME 24 rotational delay
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 disk not ready
end of file x assume rest of disk is zero
OS I/O error x report error and stop
2.4.2 RL11/RL01/RL02 Cartridge Disk (RL)
RL11 options include the ability to set units write enabled or write locked,
to set the drive size to RL01, RL02, or autosize, and to write a DEC standard
044 compliant bad block table on the last track:
SET RLn LOCKED set unit n write locked
SET RLn WRITEENABLED set unit n write enabled
SET RLn RL01 set size to RL01
SET RLn RL02 set size to RL02
SET RLn AUTOSIZE set size based on file size at attach
SET RLn BADBLOCK write bad block table on last track
The size options can be used only when a unit is not attached to a file. The
bad block option can be used only when a unit is attached to a file. Units
can also be set ENABLED or DISABLED.
The RL11 implements these registers:
name size comments
RLCS 16 control/status
RLDA 16 disk address
RLBA 16 memory address
RLBAE 6 memory address extension (not used)
RLMP..RLMP2 16 multipurpose register queue
INT 1 interrupt pending flag
ERR 1 error flag (CSR<15>)
DONE 1 device done flag (CSR<7>)
IE 1 interrupt enable flag (CSR<6>)
STIME 24 seek time, per cylinder
RTIME 24 rotational delay
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 disk not ready
end of file x assume rest of disk is zero
OS I/O error x report error and stop
2.4.3 RK611/RK06/RK07 Cartridge Disk (HK)
RK611 options include the ability to set units write enabled or write
locked, to set the drive size to RK06, RK07, or autosize, and to write
a DEC standard 044 compliant bad block table on the last track:
SET HKn LOCKED set unit n write locked
SET HKn WRITEENABLED set unit n write enabled
SET HKn RK06 set size to RK06
SET HKn RK07 set size to RK07
SET HKn AUTOSIZE set size based on file size at attach
SET HKn BADBLOCK write bad block table on last track
The size options can be used only when a unit is not attached to a file.
The bad block option can be used only when a unit is attached to a file.
Units can be set ENABLED or DISABLED. The RK611 supports the BOOT command.
The RK611 implements these registers:
name size comments
HKCS1 16 control/status 1
HKWC 16 word count
HKBA 16 bus address
HKDA 16 desired surface, sector
HKCS2 16 control/status 2
HKDS[0:7] 16 drive status, drives 0-7
HKER[0:7] 16 drive errors, drives 0-7
HKDB[0:2] 16 data buffer silo
HKDC 16 desired cylinder
HKOF 8 offset
HKMR 16 maintenance register
HKSPR 16 spare register
INT 1 interrupt pending flag
ERR 1 error flag (CSR<15>)
DONE 1 device done flag (CSR1<7>)
IE 1 interrupt enable flag (CSR1<6>)
STIME 24 seek time, per cylinder
RTIME 24 rotational delay
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 disk not ready
end of file x assume rest of disk is zero
OS I/O error x report error and stop
2.4.4 UDA50 MSCP Disk Controllers (RQ, RQB, RQC, RQD)
The simulator implements four MSCP disk controllers, RQ, RQB, RQC, RQD.
Initially, RQB, RQC, and RQD are disabled. Each RQ controller simulates
an UDA50 MSCP disk controller. RQ options include the ability to set
units write enabled or write locked, and to set the drive type to one
of many disk types:
SET RQn LOCKED set unit n write locked
SET RQn WRITEENABLED set unit n write enabled
SET RQn RX50 set type to RX50
SET RQn RX33 set type to RX33
SET RQn RD51 set type to RD51
SET RQn RD52 set type to RD52
SET RQn RD53 set type to RD53
SET RQn RD54 set type to RD54
SET RQn RD31 set type to RD31
SET RQn RA81 set type to RA81
SET RQn RA82 set type to RA82
set RQn RA71 set type to RA71
SET RQn RA72 set type to RA72
SET RQn RA90 set type to RA90
SET RQn RA92 set type to RA92
SET RQn RAUSER{=n} set type to RA81 with n MB's
SET -L RQn RAUSER{=n} set type to RA81 with n LBN's
The type options can be used only when a unit is not attached to a file.
RAUSER is a "user specified" disk; the user can specify the size of the
disk in either MB (1000000 bytes) or logical block numbers (LBN's, 512
bytes each). The minimum size is 5MB; the maximum size is 2GB without
extended addressing, 1000GB with extended addressing.
Units can also be set ENABLED or DISABLED.
Each RQ controller implements the following special SHOW commands:
SHOW RQn TYPE show drive type
SHOW RQ RINGS show command and response rings
SHOW RQ FREEQ show packet free queue
SHOW RQ RESPQ show packet response queue
SHOW RQ UNITQ show unit queues
SHOW RQ ALL show all ring and queue state
SHOW RQn UNITQ show unit queues for unit n
Each RQ controller implements these registers:
name size comments
SA 16 status/address register
S1DAT 16 step 1 init host data
CQBA 22 command queue base address
CQLNT 8 command queue length
CQIDX 8 command queue index
RQBA 22 request queue base address
RQLNT 8 request queue length
RQIDX 8 request queue index
FREE 5 head of free packet list
RESP 5 head of response packet list
PBSY 5 number of busy packets
CFLGS 16 controller flags
CSTA 4 controller state
PERR 9 port error number
CRED 5 host credits
HAT 17 host available timer
HTMO 17 host timeout value
CPKT[0:3] 5 current packet, units 0-3
PKTQ[0:3] 5 packet queue, units 0-3
UFLG[0:3] 16 unit flags, units 0-3
INT 1 interrupt request
ITIME 1 response time for initialization steps
(except for step 4)
QTIME 24 response time for 'immediate' packets
XTIME 24 response time for data transfers
PKTS[33*32] 16 packet buffers, 33W each,
32 entries
While VMS is not timing sensitive, most of the BSD-derived operating systems
(NetBSD, OpenBSD, etc) are. The QTIME and XTIME parameters are set to
values that allow these operating systems to run correctly.
Error handling is as follows:
error processed as
not attached disk not ready
end of file assume rest of disk is zero
OS I/O error report error and stop
2.5 Tapes
2.5.1 TM02/TM03/TE16/TU45/TU77 Magtapes (TU)
The TU controller implementes the Massbus family of 800/1600bpi tape
drives. TU options include the ability to select the formatter type
(TM02 or TM03), to set the drive type to one of three drives (TE16,
TU45, or TU77), and to set the drives write enabled or write locked.
SET TU TM02 set controller type to TM02
SET TU TM03 set controller type to TM03
set TUn TE16 set drive type to TE16
SET TUn TU45 set drive type to TU45
SET TUn TU77 set drive type to TU77
SET TUn LOCKED set unit write locked
SET TUn WRITEENABLED set unit write enabled
Units can be set ENABLED or DISABLED.
The TU controller implements the following registers:
name size comments
CS1 6 current operation
FC 16 frame count
FS 16 formatter status
ER 16 formatter errors
CC 16 check character
MR 16 maintenance register
TC 16 tape control register
TIME 24 operation execution time
STOP_IOE 1 stop of I/O error
Error handling is as follows:
error processed as
not attached tape not ready; if STOP_IOE, stop
end of file bad tape
OS I/O error parity error; if STOP_IOE, stop
2.5.2 TS11 Magnetic Tape (TS)
TS options include the ability to set the drive write enabled or write
locked.
SET TS LOCKED set unit write locked
SET TS WRITEENABLED set unit write enabled
The TS controller implements these registers:
name size comments
TSSR 16 status register
TSBA 16 bus address register
TSDBX 16 data buffer extension register (not used)
CHDR 16 command packet header
CADL 16 command packet low address or count
CADH 16 command packet high address
CLNT 16 command packet length
MHDR 16 message packet header
MRFC 16 message packet residual frame count
MXS0 16 message packet extended status 0
MXS1 16 message packet extended status 1
MXS2 16 message packet extended status 2
MXS3 16 message packet extended status 3
MXS4 16 message packet extended status 4
WADL 16 write char packet low address
WADH 16 write char packet high address
WLNT 16 write char packet length
WOPT 16 write char packet options
WXOPT 16 write char packet extended options
ATTN 1 attention message pending
BOOT 1 boot request pending
OWNC 1 if set, tape owns command buffer
OWNM 1 if set, tape owns message buffer
TIME 24 delay
POS 32 position
Error handling is as follows:
error processed as
not attached tape not ready
end of file (read or space) end of physical tape
(write) ignored
OS I/O error fatal tape error
2.5.3 TUK50 TMSCP Disk Controller (TQ)
The TQ controller simulates the TUK50 TMSCP disk controller. TQ options
include the ability to set units write enabled or write locked, and to
specify the controller type and tape length:
SET TQn LOCKED set unit n write locked
SET TQn WRITEENABLED set unit n write enabled
SET TQ TK50 set controller type to TK50
SET TQ TK70 set controller type to TK70
SET TQ TU81 set controller type to TU81
SET TQ TKUSER{=n} set controller type to TK50 with
tape capacity of n MB
User-specified capacity must be between 50 and 2000 MB.
The TQ controller implements the following special SHOW commands:
SHOW TQ TYPE show controller type
SHOW TQ RINGS show command and response rings
SHOW TQ FREEQ show packet free queue
SHOW TQ RESPQ show packet response queue
SHOW TQ UNITQ show unit queues
SHOW TQ ALL show all ring and queue state
SHOW TQn UNITQ show unit queues for unit n
The TQ controller implements these registers:
name size comments
SA 16 status/address register
S1DAT 16 step 1 init host data
CQBA 22 command queue base address
CQLNT 8 command queue length
CQIDX 8 command queue index
RQBA 22 request queue base address
RQLNT 8 request queue length
RQIDX 8 request queue index
FREE 5 head of free packet list
RESP 5 head of response packet list
PBSY 5 number of busy packets
CFLGS 16 controller flags
CSTA 4 controller state
PERR 9 port error number
CRED 5 host credits
HAT 17 host available timer
HTMO 17 host timeout value
CPKT[0:3] 5 current packet, units 0-3
PKTQ[0:3] 5 packet queue, units 0-3
UFLG[0:3] 16 unit flags, units 0-3
POS[0:3] 32 tape position, units 0-3
OBJP[0:3] 32 object position, units 0-3
INT 1 interrupt request
ITIME 1 response time for initialization steps
(except for step 4)
QTIME 24 response time for 'immediate' packets
XTIME 24 response time for data transfers
PKTS[33*32] 16 packet buffers, 33W each,
32 entries
Error handling is as follows:
error processed as
not attached tape not ready
end of file end of medium
OS I/O error report error and stop
2.6 Communications Devices
2.6.1 DZ11 Terminal Multiplexor (DZ)
The DZ11 is an 8-line terminal multiplexor. Up to 4 DZ11's (32 lines)
are supported. The number of lines can be changed with the command
SET DZ LINES=n set line count to n
The line count must be a multiple of 8, with a maximum of 32.
The DZ11 supports three character processing modes, 7P, 7B, and 8B:
mode input characters output characters
7P high-order bit cleared high-order bit cleared,
non-printing characters
suppressed
7B high-order bit cleared high-order bit cleared
8B no changes no changes
The default is 8B.
The DZ11 supports logging on a per-line basis. The command
SET DZ LOG=line=filename
enables logging for the specified line to the indicated file. The
command
SET DZ NOLOG=line
disables logging for the specified line and closes any open log file.
Finally, the command
SHOW DZ LOG
displays logging information for all DZ lines.
The terminal lines perform input and output through Telnet sessions
connected to a user-specified port. The ATTACH command specifies
the port to be used:
ATTACH {-am} DZ <port> set up listening port
where port is a decimal number between 1 and 65535 that is not being used
for other TCP/IP activities. The optional switch -m turns on the DZ11's
modem controls; the optional switch -a turns on active disconnects
(disconnect session if computer clears Data Terminal Ready). Without
modem control, the DZ behaves as though terminals were directly connected;
disconnecting the Telnet session does not cause any operating system-
visible change in line status.
Once the DZ is attached and the simulator is running, the DZ will listen
for connections on the specified port. It assumes that the incoming
connections are Telnet connections. The connection remains open until
disconnected by the simulated program, the Telnet client, a SET DZ
DISCONNECT command, or a DETACH DZ command.
The SHOW DZ CONNECTIONS command displays the current connections to the DZ.
The SHOW DZ STATISTICS command displays statistics for active connections.
The SET DZ DISCONNECT=linenumber disconnects the specified line.
The DZ11 implements these registers:
name size comments
CSR[0:3] 16 control/status register, boards 0-3
RBUF[0:3] 16 receive buffer, boards 0-3
LPR[0:3] 16 line parameter register, boards 0-3
TCR[0:3] 16 transmission control register, boards 0-3
MSR[0:3] 16 modem status register, boards 0-3
TDR[0:3] 16 transmit data register, boards 0-3
SAENB[0:3] 1 silo alarm enabled, boards 0-3
RXINT 4 receive interrupts, boards 3..0
TXINT 4 transmit interrupts, boards 3..0
MDMTCL 1 modem control enabled
AUTODS 1 autodisconnect enabled
The DZ11 does not support save and restore. All open connections are
lost when the simulator shuts down or the DZ is detached.
2.7 Symbolic Display and Input
The VAX780 simulator implements symbolic display and input. Display is
controlled by command line switches:
-a,-c display as ASCII data
-m display instruction mnemonics
-p display compatibility mode mnemonics
-r display RADIX50 encoding
Input parsing is controlled by the first character typed in or by command
line switches:
' or -a ASCII characters (determined by length)
" or -c ASCII string (maximum 60 characters)
-p compatibility mode instruction mnemonic
alphabetic instruction mnemonic
numeric octal number
VAX instruction input uses standard VAX assembler syntax. Compatibility
mode instruction input uses standard PDP-11 assembler syntax.
The syntax for VAX specifiers is as follows:
syntax specifier displacement comments
#s^n, #n 0n - short literal, integer only
[Rn] 4n - indexed, second specifier
follows
Rn 5n - PC illegal
(Rn) 6n - PC illegal
-(Rn) 7n - PC illegal
(Rn)+ 8n -
#i^n, #n 8F n immediate
@(Rn)+ 9n -
@#addr 9F addr absolute
{+/-}b^d(Rn) An {+/-}d byte displacement
b^d AF d - PC byte PC relative
@{+/-}b^d(Rn) Bn {+/-}d byte displacement deferred
@b^d BF d - PC byte PC relative deferred
{+/-}w^d(Rn) Cn {+/-}d word displacement
w^d CF d - PC word PC relative
@{+/-}w^d(Rn) Dn {+/-}d word displacement deferred
@w^d DF d - PC word PC relative deferred
{+/-}l^d(Rn) En {+/-}d long displacement
l^d EF d - PC long PC relative
@{+/-}l^d(Rn) Fn {+/-}d long displacement deferred
@l^d FF d - PC long PC relative deferred
If no override is given for a literal (s^ or i^) or for a displacement or PC
relative addres (b^, w^, or l^), the simulator chooses the mode automatically.