blob: c5fb8a0217f7cbe08cb3fbb285f0cc067cf35cd2 [file] [log] [blame] [raw]
To: Users
From: Bob Supnik
Subj: Nova Simulator Usage
Date: 15-Mar-2003
COPYRIGHT NOTICE
The following copyright notice applies to both the SIMH source and binary:
Original code published in 1993-2003, written by Robert M Supnik
Copyright (c) 1993-2003, Robert M Supnik
Permission is hereby granted, free of charge, to any person obtaining a
copy of this software and associated documentation files (the "Software"),
to deal in the Software without restriction, including without limitation
the rights to use, copy, modify, merge, publish, distribute, sublicense,
and/or sell copies of the Software, and to permit persons to whom the
Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in
all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL
ROBERT M SUPNIK BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER
IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN
CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
Except as contained in this notice, the name of Robert M Supnik shall not
be used in advertising or otherwise to promote the sale, use or other dealings
in this Software without prior written authorization from Robert M Supnik.
This memorandum documents the Nova simulator.
1. Simulator Files
sim/ sim_defs.h
sim_rev.h
sim_sock.h
sim_tape.h
sim_tmxr.h
scp.c
scp_tty.c
sim_sock.c
sim_tape.c
sim_tmxr.c
sim/nova/ nova_defs.h
nova_cpu.c
nova_clk.c
nova_dkp.c
nova_dsk.c
nova_lp.c
nova_mta.c
nova_plt.c
nova_sys.c
nova_tt.c
nova_tt1.c
2. Nova Features
The Nova simulator is configured as follows:
device simulates
name(s)
CPU Nova CPU with 32KW of memory
- hardware multiply/divide
PTR,PTP paper tape reader/punch
TTI,TTO console terminal
TTI1,TTO1 second terminal
LPT line printer
PLT plotter
CLK real-time clock
DK head-per-track disk controller
DP moving head disk controller with four drives
MT magnetic tape controller with eight drives
The Nova simulator implements these unique stop conditions:
- reference to undefined I/O device, and STOP_DEV is set
- more than INDMAX indirect addresses are detected during
an interrupt
- more than INDMAX indirect addresses are detected during
memory reference address decoding
The Nova loader supports standard binary format tapes. The DUMP command
is not implemented.
Most devices can be disabled or enabled, by the commands:
SET <dev> DISABLED
SET <dev> ENABLED
All devices are enabled by default.
2.1 CPU
The only CPU options are the presence of the optional instructions
and the size of main memory.
SET CPU MDV enable multiply/divide
SET CPU NOVA3 enable Nova3 instructions
SET CPU NOVA4 enable Nova4 instructions
SET CPU NONE disable all optional instructions
SET CPU 4K set memory size = 4K
SET CPU 8K set memory size = 8K
SET CPU 12K set memory size = 12K
SET CPU 16K set memory size = 16K
SET CPU 20K set memory size = 20K
SET CPU 24K set memory size = 24K
SET CPU 28K set memory size = 28K
SET CPU 32K set memory size = 32K
(MDV = unsigned multiply/divide instructions)
(Nova 3 = unsigned multiply/divide, stack, trap instructions)
(Nova 4 = unsigned and signed multiply/divide, stack, byte, trap instructions)
If memory size is being reduced, and the memory being truncated contains
non-zero data, the simulator asks for confirmation. Data in the truncated
portion of memory is lost. Initial memory size is 32K.
CPU registers include the visible state of the processor as well as the
control registers for the interrupt system.
name size comments
PC 15 program counter
AC0..AC3 16 accumulators 0..3
C 1 carry
SR 16 front panel switches
PI 16 priority interrupt mask
ION 1 interrupt enable
ION_DELAY 1 interrupt enable delay for ION
PWR 1 power fail interrupt
INT 15 interrupt pending flags
BUSY 15 device busy flags
DONE 15 device done flags
DISABLE 15 device interrupt disable flags
STOP_DEV 1 stop on undefined IOT
INDMAX 15 maximum number of nested indirects
PCQ[0:63] 15 PC prior to last JMP, JMS, or interrupt;
most recent PC change first
WRU 8 interrupt character
2.2 Programmed I/O Devices
2.2.1 Paper Tape Reader (PTR)
The paper tape reader (PTR) reads data from a disk file. The POS
register specifies the number of the next data item to be read. Thus,
by changing POS, the user can backspace or advance the reader.
The paper tape reader implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
POS 32 position in the input file
TIME 24 time from I/O initiation to interrupt
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 out of tape or paper
end of file 1 report error and stop
0 out of tape or paper
OS I/O error x report error and stop
2.2.2 Paper Tape Punch (PTP)
The paper tape punch (PTP) writes data to a disk file. The POS
register specifies the number of the next data item to be written.
Thus, by changing POS, the user can backspace or advance the punch.
The paper tape punch implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
POS 32 position in the output file
TIME 24 time from I/O initiation to interrupt
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 out of tape or paper
OS I/O error x report error and stop
2.2.3 Terminal Input (TTI)
The terminal input polls the console keyboard for input. Terminal
input options include the ability to set ANSI mode or limited Dasher
compatibility mode:
SET TTI ANSI normal mode
SET TTI DASHER Dasher mode
Setting either TTI or TTO changes both devices. In Dasher mode, carriage
return is changed to newline on input, and ^X is changed to backspace.
The terminal input implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
POS 32 number of characters input
TIME 24 keyboard polling interval
2.2.4 Terminal Output (TTO)
The terminal output writes to the simulator console window. Terminal
output options include the the ability to set ANSI mode or limited
Dasher compatibility mode:
SET TTO ANSI normal mode
SET TTO DASHER Dasher mode
Setting either TTI or TTO changes both devices. In Dasher mode, carriage
return is changed to newline on input, and ^X is changed to backspace.
The terminal output implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
POS 32 number of characters output
TIME 24 time from I/O initiation to interrupt
2.2.5 Line Printer (LPT)
The line printer (LPT) writes data to a disk file. The POS register
specifies the number of the next data item to be written. Thus,
by changing POS, the user can backspace or advance the printer.
The line printer implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
POS 32 position in the output file
TIME 24 time from I/O initiation to interrupt
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 out of paper
OS I/O error x report error and stop
2.2.6 Real-Time Clock (CLK)
The real-time clock (CLK) line frequency can be adjusted as follows:
SET CLK 60HZ set line frequency to 60Hz
SET CLK 50HZ set line frequency to 50Hz
The default is 60Hz.
The clock implements these registers:
name size comments
SELECT 2 selected clock interval
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
TIME0 24 clock frequency, select = 0
TIME1 24 clock frequency, select = 1
TIME2 24 clock frequency, select = 2
TIME3 24 clock frequency, select = 3
The real-time clock autocalibrates; the clock interval is adjusted up or
down so that the clock tracks actual elapsed time.
2.2.7 Plotter (PTP)
The plotter (PLT) writes data to a disk file. The POS register
specifies the number of the next data item to be written. Thus,
by changing POS, the user can backspace or advance the plotter.
The plotter implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
POS 32 position in the output file
TIME 24 time from I/O initiation to interrupt
STOP_IOE 1 stop on I/O error
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 out of tape or paper
OS I/O error x report error and stop
2.2.8 Second Terminal (TTI1, TTO1)
The second terminal consists of two independent devices, TTI1 and TTO1.
The additional terminal performs input and output through a Telnet session
connecting into a user-specified port. The ATTACH command specifies the
port to be used:
ATTACH TTI1 <port> set up listening port
where port is a decimal number between 1 and 65535 that is not being used
for other TCP/IP activities.
Once TTI1 is attached and the simulator is running, the terminal listens
for a connection on the specified port. It assumes that the incoming
connection is a Telnet connection. The connection remain opens until
disconnected by the Telnet client, or by a DETACH TTI1 command.
The second terminal has two options, recognized on both devices, for
setting limited Dasher-compatibility mode or ANSI mode:
SET TTI1 ANSI normal mode
SET TTI1 DASHER Dasher mode
SET TTO1 ANSI normal mode
SET TTO1 DASHER Dasher mode
Setting either TTI1 or TTO1 changes both devices. In Dasher mode, carriage
return is changed to newline on input, and ^X is changed to backspace.
The SHOW TTI1 CONNECTIONS command displays the current connection to TTI1.
The SHOW TTI1 STATISTICS command displays statistics for the current connection.
The SET TTI1 DISCONNECT{=0} disconnects the current connection.
The second terminal input implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
TIME 24 keyboard polling interval
The second terminal output implements these registers:
name size comments
BUF 8 last data item processed
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
TIME 24 time from I/O initiation to interrupt
2.3 Fixed Head Disk (DK)
Fixed head disk options include the ability to set the number of platters
to a fixed value between 1 and 8, or to autosize the number of platters
from the attached file:
SET RF 1P one platter (256K)
SET RF 2P two platters (512K)
SET RF 3P three platters (768K)
SET RF 4P four platters (1024K)
SET RF 5P five platters (1280K)
SET RF 6P six platters (1536K)
SET RF 7P seven platters (1792K)
SET RF 8P eight platters (2048K)
SET RF AUTOSIZE autosized on attach
The default is 1P (minimum size).
The fixed head disk controller implements these registers:
name size comments
STAT 16 status
DA 16 disk address
MA 16 memory address
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 device disable flag
INT 1 interrupt pending flag
WLK 8 write lock switches
TIME 24 rotational delay, per sector
STOP_IOE 1 stop on I/O error
The fixed head disk controller supports the BOOT command.
Error handling is as follows:
error STOP_IOE processed as
not attached 1 report error and stop
0 disk not ready
Fixed head disk data files are buffered in memory; therefore, end of file
and OS I/O errors cannot occur.
2.4 Moving Head Disk (DP)
Moving head disk options include the ability to make units write enabled or
write locked, and to select the type of drive:
SET DPn LOCKED set unit n write locked
SET DPn WRITEENABLED set unit n write enabled
SET DPn FLOPPY set unit n to floppy disk
SET DPn D31 set unit n to Diablo 31
SET DPn D44 set unit n to Diablo 44
SET DPn C111 set unit n to Century 111
SET DPn C114 set unit n to Century 114
SET DPn 6225 set unit n to 6225
SET DPn 6099 set unit n to 6099
SET DPn 6227 set unit n to 6227
SET DPn 6070 set unit n to 6070
SET DPn 6103 set unit n to 6103
SET DPn 4231 set unit n to 4231
Units can also be set ONLINE or OFFLINE. The moving head disk controller
supports the BOOT command.
All drives have 256 16b words per sector. The other disk parameters are:
drive cylinders surfaces sectors size (MW) DG models
floppy 77 1 8 .158 6038
D31 203 2 12 1.247 4047, 4237, 4238
D44 408 4 12 5.014 4234, 6045
C111 203 10 6 3.118 4048
C114 203 20 12 12.472 4057, 2314
6225 245 2 20 2.508
6099 192 4 32 6.291
6227 245 6 20 7.526
6070 408 4 24 10.027
6103 192 8 32 12.583
4231 411 19 23 45.979
The moving head disk controller implements these registers:
name size comments
FCCY 16 flags, command, cylinder
USSC 16 unit, surface, sector, count
STAT 16 status
MA 16 memory address
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
STIME 24 seek time, per cylinder
RTIME 24 rotational delay
Error handling is as follows:
error processed as
not attached disk not ready
end of file assume rest of disk is zero
OS I/O error report error and stop
2.5 Magnetic Tape (MT)
Magnetic tape options include the ability to make units write enabled or
or write locked.
SET MTn LOCKED set unit n write locked
SET MTn WRITEENABLED set unit n write enabled
Units can also be set ONLINE or OFFLINE. The magnetic tape controller
supports the BOOT command.
The magnetic tape controller implements these registers:
name size comments
CU 16 command, unit
MA 16 memory address
WC 16 word count
STA1 16 status word 1
STA2 16 status word 2
EP 1 extended polling mode (not supported)
BUSY 1 device busy flag
DONE 1 device done flag
DISABLE 1 interrupt disable flag
INT 1 interrupt pending flag
STOP_IOE 1 stop on I/O error
CTIME 24 controller delay
RTIME 24 record delay
UST[0:7] 32 unit status, units 0-7
POS[0:7] 31 position, units 0-7
Error handling is as follows:
error processed as
not attached tape not ready
end of file bad tape
OS I/O error report error and stop
2.6 Symbolic Display and Input
The Nova simulator implements symbolic display and input. Display is
controlled by command line switches:
-a display as ASCII character
-c display as two character ASCII string
-m display instruction mnemonics
Input parsing is controlled by the first character typed in or by command
line switches:
' or -a ASCII character
" or -c two character ASCII string
alphabetic instruction mnemonic
numeric octal number
Instruction input uses standard Nova assembler syntax. There are three
instruction classes: memory reference, IOT, and operate.
Memory reference instructions have the format
memref {ac,}{@}address{,index}
LDA and STA require an initial register; ISZ, DSZ, JSR, and JMP do not.
The syntax for addresses and indices is as follows:
syntax mode displacement comments
0 <= n < 0400 0 n
{+/-}n >= 0400 1 {+/-}n - PC must be in range [-200, 177]
invalid on disk
.+/-n 1 {+/-}n must be in range [-200, 177]
{+/-}n,2 2 {+/-}n must be in range [-200, 177]
{+/-}n,3 3 {+/-}n must be in range [-200, 177]
IOT instructions have one of four formats
syntax example
iot HALT
iot reg INTA
iot device SKPDN
iot reg,device DOAS
Devices may be specified as mnemonics or as numbers in the range 0 - 077.
Operate instructions have the format
opcode{#} reg,reg{,skip}
In all Nova instructions, blanks may be substituted for commas as field