| <!DOCTYPE html> |
| |
| <html> |
| <head> |
| <meta charset="UTF-8"> |
| <link href="style.css" type="text/css" rel="stylesheet"> |
| <title>MOVZX—Move with Zero-Extend </title></head> |
| <body> |
| <h1>MOVZX—Move with Zero-Extend</h1> |
| <table> |
| <tr> |
| <th>Opcode</th> |
| <th>Instruction</th> |
| <th>Op/En</th> |
| <th>64-Bit Mode</th> |
| <th>Compat/Leg Mode</th> |
| <th>Description</th></tr> |
| <tr> |
| <td>0F B6 /<em>r</em></td> |
| <td>MOVZX <em>r16, r/m8</em></td> |
| <td>RM</td> |
| <td>Valid</td> |
| <td>Valid</td> |
| <td>Move byte to word with zero-extension.</td></tr> |
| <tr> |
| <td>0F B6 /<em>r</em></td> |
| <td>MOVZX <em>r32, r/m8</em></td> |
| <td>RM</td> |
| <td>Valid</td> |
| <td>Valid</td> |
| <td>Move byte to doubleword, zero-extension.</td></tr> |
| <tr> |
| <td>REX.W + 0F B6 /<em>r</em></td> |
| <td>MOVZX <em>r64, r/m8*</em></td> |
| <td>RM</td> |
| <td>Valid</td> |
| <td>N.E.</td> |
| <td>Move byte to quadword, zero-extension.</td></tr> |
| <tr> |
| <td>0F B7 /<em>r</em></td> |
| <td>MOVZX <em>r32, r/m16</em></td> |
| <td>RM</td> |
| <td>Valid</td> |
| <td>Valid</td> |
| <td>Move word to doubleword, zero-extension.</td></tr> |
| <tr> |
| <td>REX.W + 0F B7 /<em>r</em></td> |
| <td>MOVZX <em>r64, r/m16</em></td> |
| <td>RM</td> |
| <td>Valid</td> |
| <td>N.E.</td> |
| <td>Move word to quadword, zero-extension.</td></tr></table> |
| <p><strong>NOTES:</strong></p> |
| <p>*</p> |
| <p>In 64-bit mode, r/m8 can not be encoded to access the following byte registers if the REX prefix is used: AH, BH, CH, DH.</p> |
| <h3>Instruction Operand Encoding</h3> |
| <table> |
| <tr> |
| <td>Op/En</td> |
| <td>Operand 1</td> |
| <td>Operand 2</td> |
| <td>Operand 3</td> |
| <td>Operand 4</td></tr> |
| <tr> |
| <td>RM</td> |
| <td>ModRM:reg (w)</td> |
| <td>ModRM:r/m (r)</td> |
| <td>NA</td> |
| <td>NA</td></tr></table> |
| <h2>Description</h2> |
| <p>Copies the contents of the source operand (register or memory location) to the destination operand (register) and zero extends the value. The size of the converted value depends on the operand-size attribute.</p> |
| <p>In 64-bit mode, the instruction’s default operation size is 32 bits. Use of the REX.R prefix permits access to addi-tional registers (R8-R15). Use of the REX.W prefix promotes operation to 64 bit operands. See the summary chart at the beginning of this section for encoding data and limits.</p> |
| <h2>Operation</h2> |
| <pre>DEST ← ZeroExtend(SRC);</pre> |
| <h2>Flags Affected</h2> |
| <p>None.</p> |
| <h2>Protected Mode Exceptions</h2> |
| <table class="exception-table"> |
| <tr> |
| <td>#GP(0)</td> |
| <td> |
| <p>If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.</p> |
| <p>If the DS, ES, FS, or GS register contains a NULL segment selector.</p></td></tr> |
| <tr> |
| <td>#SS(0)</td> |
| <td>If a memory operand effective address is outside the SS segment limit.</td></tr> |
| <tr> |
| <td>#PF(fault-code)</td> |
| <td>If a page fault occurs.</td></tr> |
| <tr> |
| <td>#AC(0)</td> |
| <td>If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.</td></tr> |
| <tr> |
| <td>#UD</td> |
| <td>If the LOCK prefix is used.</td></tr></table> |
| <h2>Real-Address Mode Exceptions</h2> |
| <table class="exception-table"> |
| <tr> |
| <td>#GP</td> |
| <td>If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.</td></tr> |
| <tr> |
| <td>#SS</td> |
| <td>If a memory operand effective address is outside the SS segment limit.</td></tr> |
| <tr> |
| <td>#UD</td> |
| <td>If the LOCK prefix is used.</td></tr></table> |
| <h2>Virtual-8086 Mode Exceptions</h2> |
| <table class="exception-table"> |
| <tr> |
| <td>#GP(0)</td> |
| <td>If a memory operand effective address is outside the CS, DS, ES, FS, or GS segment limit.</td></tr> |
| <tr> |
| <td>#SS(0)</td> |
| <td>If a memory operand effective address is outside the SS segment limit.</td></tr> |
| <tr> |
| <td>#PF(fault-code)</td> |
| <td>If a page fault occurs.</td></tr> |
| <tr> |
| <td>#AC(0)</td> |
| <td>If alignment checking is enabled and an unaligned memory reference is made.</td></tr> |
| <tr> |
| <td>#UD</td> |
| <td>If the LOCK prefix is used.</td></tr></table> |
| <h2>Compatibility Mode Exceptions</h2> |
| <p>Same exceptions as in protected mode.</p> |
| <h2>64-Bit Mode Exceptions</h2> |
| <table class="exception-table"> |
| <tr> |
| <td>#SS(0)</td> |
| <td>If a memory address referencing the SS segment is in a non-canonical form.</td></tr> |
| <tr> |
| <td>#GP(0)</td> |
| <td>If the memory address is in a non-canonical form.</td></tr> |
| <tr> |
| <td>#PF(fault-code)</td> |
| <td>If a page fault occurs.</td></tr> |
| <tr> |
| <td>#AC(0)</td> |
| <td>If alignment checking is enabled and an unaligned memory reference is made while the current privilege level is 3.</td></tr> |
| <tr> |
| <td>#UD</td> |
| <td>If the LOCK prefix is used.</td></tr></table></body></html> |