blob: 60841c2ae33fe4be85de8a660ca7dbb1706014c5 [file] [log] [blame] [view] [raw]
Latest status for I7000 Cpus:
## i701
* Largely untested.
## i704
* SAP works.
* Fort2 working.
## i7010
* PR155 works.
* PR108 works.
* Most Diags appear to pass without serious error.
* Protection mode has some errors left.
* Protection mode does not handle setting H or L to 0.
## i7070
* Will load Diags, need to remember how to run them to run
* tests on machine.
## i7080
* Sort of working.
* RWW, ECB untested.
* TLx instructions implimented, untested, see 8SE
* Will boot from card.
* Tape system appear to be working.
* 8CU10B errors:
410, 412, 413, 414, 418, 419, 420-427 error becuase
storage is not parity checked.
440 divide not producing correct sign on error.
## i7090
* Working with exceptions.
* Known bugs:
* DFDP/DFMP Sometimes off by +/-1 or 2 in least signifigant part of result.
* EAD +n + -n should be -0 is +0
* Not all channel skips working for 9P01C.
* HTx Not sure what problems are, does not quite work.
* DKx Sometimes fails diagnostics with missing inhibit of interrupt.
* CTSS works.
* IBSYS works.
* Stand alone assembler works.
* Lisp 1.5 works.
* Signifigence mode Not tested, Test Code Needed.